موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
معدات الغرف النظيفة المحددة للصناعة

الصيدلانية تمرير من خلال الأوتوكلاف

A double-door cleanroom steam sterilizer that transfers processed loads between segregated areas through an interlocked 316L stainless chamber.
  • Interlocked Double Doors
  • 316L Pressure Chamber
  • Clean-Steam Sterilization
  • Trolley Loading System
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The pharmaceutical pass-through autoclave mounts between segregated rooms so loads enter from one side and exit from the other only after the completed sterilization cycle. A jacketed 316L stainless chamber, vacuum-assisted air removal and clean-steam distribution support porous, wrapped or component loads. Door interlocks, loading rails and dedicated trolleys maintain separation and safe material movement across the wall boundary.

الخصائص الرئيسية

Opposing interlocked doors prevent an unsterilized load path through the cleanroom boundary.

Jacketed 316L chamber and vacuum system support controlled steam penetration and drying.

Anti-tip rails and dedicated trolleys guide heavy loads through the chamber.

PLC control records cycle temperature, pressure and phase status for operational review.

مخاوف المنتج للعملاء

Materials must cross room boundaries without bypassing sterilization or permitting both sides of the pressure chamber to open together.

Manual transfer can reconnect dirty and clean sides.Door interlocks release the discharge side only after the configured cycle completes.
Trapped air prevents uniform steam contact in porous loads.Vacuum-assisted air removal and controlled steam pulses improve chamber penetration.
Heavy trolleys are difficult to align with the chamber.Fixed anti-tip loading rails provide a repeatable guided path through the sterilizer.
Cycle deviations are hard to investigate without recorded data.PLC monitoring records pressure, temperature and phase progression for each load.

تطبيقات نموذجية

Pharmaceutical component sterilizationCleanroom tool and garment loadsBiotechnology production materialsHigh-containment pass-through processing

المعلمات الفنية

Typical construction values for a pharmaceutical pass-through steam autoclave are listed below.

المواد الأساسية316L stainless steel pressure chamber with stainless loading rails and silicone door seals
سمك اللوحة60-120 mm insulated external panels
العرض الفعال600-1500 mm clear chamber width
الحد الأقصى الطولUp to 3000 mm usable chamber length
الصلب يواجه سمك1.2-2.0 mm external stainless cladding
الكثافة الأساسية80-140 kg/m³ for high-temperature insulated cladding
الموصلية الحرارية0.040-0.060 W/(m·K) for insulated cladding
إنهاء السطحPolished 316L chamber with satin stainless exterior panels
نوع المشتركWelded jacketed pressure chamber with interlocked gasketed doors, sanitary steam piping and guided trolley rails
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Rectangular or cylindrical chamberHinged or powered sliding doorsClean-steam generator and vacuum dryingEffluent retention and filtered venting

Planning a Pharmaceutical Pass-Through Autoclave specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat

الرئيسية

المنتجات

الأخبار

من نحن

اتصل بنا