A double-door cleanroom steam sterilizer that transfers processed loads between segregated areas through an interlocked 316L stainless chamber.
  • Interlocked Double Doors
  • 316L Pressure Chamber
  • Clean-Steam Sterilization
  • Trolley Loading System
Permintaan untuk kutipan Browse Produk

Perkenalan produk

The pharmaceutical pass-through autoclave mounts between segregated rooms so loads enter from one side and exit from the other only after the completed sterilization cycle. A jacketed 316L stainless chamber, vacuum-assisted air removal and clean-steam distribution support porous, wrapped or component loads. Door interlocks, loading rails and dedicated trolleys maintain separation and safe material movement across the wall boundary.

Fitur utama:

Opposing interlocked doors prevent an unsterilized load path through the cleanroom boundary.

Jacketed 316L chamber and vacuum system support controlled steam penetration and drying.

Anti-tip rails and dedicated trolleys guide heavy loads through the chamber.

PLC control records cycle temperature, pressure and phase status for operational review.

Kekhawatiran produk pelanggan

Materials must cross room boundaries without bypassing sterilization or permitting both sides of the pressure chamber to open together.

Manual transfer can reconnect dirty and clean sides.Door interlocks release the discharge side only after the configured cycle completes.
Trapped air prevents uniform steam contact in porous loads.Vacuum-assisted air removal and controlled steam pulses improve chamber penetration.
Heavy trolleys are difficult to align with the chamber.Fixed anti-tip loading rails provide a repeatable guided path through the sterilizer.
Cycle deviations are hard to investigate without recorded data.PLC monitoring records pressure, temperature and phase progression for each load.

Aplikasi yang Tipis

Pharmaceutical component sterilizationCleanroom tool and garment loadsBiotechnology production materialsHigh-containment pass-through processing

Parameter teknis

Typical construction values for a pharmaceutical pass-through steam autoclave are listed below.

Bahan inti316L stainless steel pressure chamber with stainless loading rails and silicone door seals
Ketebalan Panel (Panel Thickness)60-120 mm insulated external panels
Efektif lebar600-1500 mm clear chamber width
Panjang maksimumUp to 3000 mm usable chamber length
Baja menghadap ketebalan1.2-2.0 mm external stainless cladding
Kepadatan inti (core density)80-140 kg/m³ for high-temperature insulated cladding
Konduktivitas Termal (Thermal Conductivity)0.040-0.060 W/(m·K) for insulated cladding
Permukaan selesaiPolished 316L chamber with satin stainless exterior panels
Jenis BersamaWelded jacketed pressure chamber with interlocked gasketed doors, sanitary steam piping and guided trolley rails
Customization (Kustomisasi)Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi.

Pilihan yang tersedia

Rectangular or cylindrical chamberHinged or powered sliding doorsClean-steam generator and vacuum dryingEffluent retention and filtered venting

Planning a Pharmaceutical Pass-Through Autoclave specification?

Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bicaralah dengan tim kami
Email Kami WhatsApp WhatsApp WhatsApp WhatsApp WeChat adalah

Beranda

Produk

Berita

Tentang Kami

Hubungi Kami