クリーンルーム機器と無菌施設の必需品のワンストップサプライヤー国際プロジェクト支援
Open mobile navigationClose mobile navigation
ホーム / 製品 / 業界特有のクリーンルーム機器 / Pharmaceutical Pass-Through Autoclave
業界特有のクリーンルーム機器

Pharmaceutical パススルーオートクレーブ

A double-door cleanroom steam sterilizer that transfers processed loads between segregated areas through an interlocked 316L stainless chamber.
  • Interlocked Double Doors
  • 316L Pressure Chamber
  • Clean-Steam Sterilization
  • Trolley Loading System
見積もりリクエスト 製品案内

商品紹介

The pharmaceutical pass-through autoclave mounts between segregated rooms so loads enter from one side and exit from the other only after the completed sterilization cycle. A jacketed 316L stainless chamber, vacuum-assisted air removal and clean-steam distribution support porous, wrapped or component loads. Door interlocks, loading rails and dedicated trolleys maintain separation and safe material movement across the wall boundary.

主要な特徴

Opposing interlocked doors prevent an unsterilized load path through the cleanroom boundary.

Jacketed 316L chamber and vacuum system support controlled steam penetration and drying.

Anti-tip rails and dedicated trolleys guide heavy loads through the chamber.

PLC control records cycle temperature, pressure and phase status for operational review.

お客様の製品に関する懸念事項

Materials must cross room boundaries without bypassing sterilization or permitting both sides of the pressure chamber to open together.

Manual transfer can reconnect dirty and clean sides.Door interlocks release the discharge side only after the configured cycle completes.
Trapped air prevents uniform steam contact in porous loads.Vacuum-assisted air removal and controlled steam pulses improve chamber penetration.
Heavy trolleys are difficult to align with the chamber.Fixed anti-tip loading rails provide a repeatable guided path through the sterilizer.
Cycle deviations are hard to investigate without recorded data.PLC monitoring records pressure, temperature and phase progression for each load.

典型的な用途

Pharmaceutical component sterilizationCleanroom tool and garment loadsBiotechnology production materialsHigh-containment pass-through processing

技術的なパラメータ

Typical construction values for a pharmaceutical pass-through steam autoclave are listed below.

コア材料316L stainless steel pressure chamber with stainless loading rails and silicone door seals
パネルの厚さ60-120 mm insulated external panels
有効幅600-1500 mm clear chamber width
最大長さUp to 3000 mm usable chamber length
鋼鉄の厚さを直面する1.2-2.0 mm external stainless cladding
コア密度80-140 kg/m³ for high-temperature insulated cladding
熱伝導率0.040-0.060 W/(m·K) for insulated cladding
表面仕上げPolished 316L chamber with satin stainless exterior panels
ジョイントタイプWelded jacketed pressure chamber with interlocked gasketed doors, sanitary steam piping and guided trolley rails
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

Rectangular or cylindrical chamberHinged or powered sliding doorsClean-steam generator and vacuum dryingEffluent retention and filtered venting

Planning a Pharmaceutical Pass-Through Autoclave specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する
メール送信 WhatsApp WeChat

ホーム

製品

ニュース

会社概要

お問い合わせ