Ваш универсальный поставщик оборудования для чистых помещений и асептических средствПоддержка международных проектов
Open mobile navigationClose mobile navigation
Оборудование для чистых помещений

Фармацевтический автоклав

A double-door cleanroom steam sterilizer that transfers processed loads between segregated areas through an interlocked 316L stainless chamber.
  • Interlocked Double Doors
  • 316L Pressure Chamber
  • Clean-Steam Sterilization
  • Trolley Loading System
Запрос котировки Просмотреть продукты

Введение продукции

The pharmaceutical pass-through autoclave mounts between segregated rooms so loads enter from one side and exit from the other only after the completed sterilization cycle. A jacketed 316L stainless chamber, vacuum-assisted air removal and clean-steam distribution support porous, wrapped or component loads. Door interlocks, loading rails and dedicated trolleys maintain separation and safe material movement across the wall boundary.

Основные характеристики

Opposing interlocked doors prevent an unsterilized load path through the cleanroom boundary.

Jacketed 316L chamber and vacuum system support controlled steam penetration and drying.

Anti-tip rails and dedicated trolleys guide heavy loads through the chamber.

PLC control records cycle temperature, pressure and phase status for operational review.

Обеспокоенность клиентов продуктами

Materials must cross room boundaries without bypassing sterilization or permitting both sides of the pressure chamber to open together.

Manual transfer can reconnect dirty and clean sides.Door interlocks release the discharge side only after the configured cycle completes.
Trapped air prevents uniform steam contact in porous loads.Vacuum-assisted air removal and controlled steam pulses improve chamber penetration.
Heavy trolleys are difficult to align with the chamber.Fixed anti-tip loading rails provide a repeatable guided path through the sterilizer.
Cycle deviations are hard to investigate without recorded data.PLC monitoring records pressure, temperature and phase progression for each load.

Типичные приложения

Pharmaceutical component sterilizationCleanroom tool and garment loadsBiotechnology production materialsHigh-containment pass-through processing

Технические параметры

Typical construction values for a pharmaceutical pass-through steam autoclave are listed below.

Основной материал316L stainless steel pressure chamber with stainless loading rails and silicone door seals
Толщина панели60-120 mm insulated external panels
эффективная ширина600-1500 mm clear chamber width
Максимальная длинаUp to 3000 mm usable chamber length
Толщина линий стали1.2-2.0 mm external stainless cladding
Плотность ядра80-140 kg/m³ for high-temperature insulated cladding
Теплопроводимость0.040-0.060 W/(m·K) for insulated cladding
Поверхностная отделкаPolished 316L chamber with satin stainless exterior panels
Объединенный типWelded jacketed pressure chamber with interlocked gasketed doors, sanitary steam piping and guided trolley rails
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Доступные варианты

Rectangular or cylindrical chamberHinged or powered sliding doorsClean-steam generator and vacuum dryingEffluent retention and filtered venting

Planning a Pharmaceutical Pass-Through Autoclave specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.

Поговорите с нашей командой
Электронная почта WhatsApp WeChat