Sala limpa Laminar Fluxo de teto
- Full-Surface HEPA Supply
- Uniform Low-Velocity Airflow
- Modular Filter Bank
- Integrated Service and Lighting Zones
Introdução do produto
The cleanroom laminar flow ceiling combines a sealed supply plenum, multiple terminal HEPA filters and a continuous perforated or textile diffuser surface above the protected area. Airflow is balanced across several duct inlets and filter cells so the discharge velocity remains even from edge to center. The broad downward field sweeps airborne particles away from an operating table, filling line or open product zone with minimal lateral induction. Bolted modular sections accommodate lighting, service columns and ceiling equipment while maintaining sealed filter and perimeter interfaces.
Características-chave
The continuous diffuser membrane or perforated face straightens local filter jets into a low-turbulence downward field.
Separate inlet plenums and balancing points allow edge and center zones to be equalized independently.
Modular structural frames accept sealed lighting and service openings without breaking the surrounding clean-air surface.
Preocupações do produto do cliente
A laminar ceiling must deliver nearly uniform velocity over a large footprint while fitting lights, equipment rails and service penetrations around the protected zone.
Aplicações típicas
Parâmetros técnicos
Representative construction and size ranges for a modular HEPA-filtered laminar flow ceiling are shown below.
| Material principal | Glass-microfiber H14 HEPA filter packs in aluminum frames with polyurethane or gel seals |
|---|---|
| Painel de espessura | 0.8–1.2 mm plenum panels and 1.0–2.0 mm structural frame sections |
| Largura efetiva | 1800–3500 mm typical protected ceiling width |
| Comprimento máximo | Up to 3500 mm in standard modular arrays, with larger custom assemblies |
| Aço enfrentando espessura | 0.8–1.2 mm powder-coated or stainless plenum facing |
| Densidade Core | Approximately 8000 kg/m³ for the optional 304 stainless-steel plenum and frame surfaces |
| Condutividade térmica | Approximately 14–16 W/(m·K) for the optional 304 stainless-steel plenum and frame surfaces |
| Superfície acabado | White powder-coated steel or brushed 304 stainless steel with cleanable diffuser membrane |
| Tipo conjunto | Bolted gasketed ceiling modules with individually sealed HEPA cells and sealed service penetrations |
| Customização | Disponível com base na aplicação pretendida e no ambiente operacional. |
Opções disponíveis
Planning a Cleanroom Laminar Flow Ceiling specification?
Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Inglês
Alemão
Língua árabe
Francês
Língua indonésia
Japonês
Coreano
Língua malaia
Portuguêsatual
Língua russa
Espanhol
Tailandês
Língua turca
Vietnã