ฝ้าเพดานลามิเนตการไหลของห้องสะอาด
- Full-Surface HEPA Supply
- Uniform Low-Velocity Airflow
- ธนาคารกรองแบบแยกส่วน รายละเอียดเพิ่มเติม:
- Integrated Service and Lighting Zones
การแนะนําสินค้า
The cleanroom laminar flow ceiling combines a sealed supply plenum, multiple terminal HEPA filters and a continuous perforated or textile diffuser surface above the protected area. Airflow is balanced across several duct inlets and filter cells so the discharge velocity remains even from edge to center. The broad downward field sweeps airborne particles away from an operating table, filling line or open product zone with minimal lateral induction. Bolted modular sections accommodate lighting, service columns and ceiling equipment while maintaining sealed filter and perimeter interfaces.
คุณสมบัติที่สําคัญ
The continuous diffuser membrane or perforated face straightens local filter jets into a low-turbulence downward field.
Separate inlet plenums and balancing points allow edge and center zones to be equalized independently.
Modular structural frames accept sealed lighting and service openings without breaking the surrounding clean-air surface.
ความกังวลของลูกค้าเกี่ยวกับผลิตภัณฑ์
A laminar ceiling must deliver nearly uniform velocity over a large footprint while fitting lights, equipment rails and service penetrations around the protected zone.
การใช้งานทั่วไป
พารามิเตอร์ทางเทคนิค
Representative construction and size ranges for a modular HEPA-filtered laminar flow ceiling are shown below.
| วัสดุหลัก | Glass-microfiber H14 HEPA filter packs in aluminum frames with polyurethane or gel seals |
|---|---|
| ความหนาของแผง | 0.8–1.2 mm plenum panels and 1.0–2.0 mm structural frame sections |
| ความกว้างที่มีประสิทธิภาพ | 1800–3500 mm typical protected ceiling width |
| ความยาวสูงสุด | Up to 3500 mm in standard modular arrays, with larger custom assemblies |
| ความหนาของเหล็กหันหน้า | 0.8–1.2 mm powder-coated or stainless plenum facing |
| ความหนาแน่นหลัก | Approximately 8000 kg/m³ for the optional 304 stainless-steel plenum and frame surfaces |
| การนําความร้อน | Approximately 14–16 W/(m·K) for the optional 304 stainless-steel plenum and frame surfaces |
| เสร็จสิ้นพื้นผิว | White powder-coated steel or brushed 304 stainless steel with cleanable diffuser membrane |
| ประเภทร่วม | Bolted gasketed ceiling modules with individually sealed HEPA cells and sealed service penetrations |
| การปรับแต่ง | สามารถใช้ได้ตามแอปพลิเคชันที่ตั้งใจไว้และสภาพแวดล้อมการทํางาน |
ตัวเลือกที่มีอยู่
Planning a Cleanroom Laminar Flow Ceiling specification?
ส่งมิติของคุณเงื่อนไขการติดตั้งเป้าหมายประสิทธิภาพและผิวที่ต้องการ

ภาษาอังกฤษ
ภาษาเยอรมัน
ภาษาอาหรับ
ฝรั่งเศส
ภาษาอินโดนีเซีย
ภาษาญี่ปุ่น
ภาษาเกาหลี
ภาษามาเลย์
ภาษาโปรตุเกส
ภาษารัสเซีย
ภาษาสเปน
ภาษาไทยปัจจุบัน
ภาษาตุรกี
ภาษาเวียดนาม