Reinraum Laminar Flow Decke
- Full-Surface HEPA Supply
- Uniform Low-Velocity Airflow
- Modular Filter Bank
- Integrated Service and Lighting Zones
Produkteinführung
The cleanroom laminar flow ceiling combines a sealed supply plenum, multiple terminal HEPA filters and a continuous perforated or textile diffuser surface above the protected area. Airflow is balanced across several duct inlets and filter cells so the discharge velocity remains even from edge to center. The broad downward field sweeps airborne particles away from an operating table, filling line or open product zone with minimal lateral induction. Bolted modular sections accommodate lighting, service columns and ceiling equipment while maintaining sealed filter and perimeter interfaces.
Key Features
The continuous diffuser membrane or perforated face straightens local filter jets into a low-turbulence downward field.
Separate inlet plenums and balancing points allow edge and center zones to be equalized independently.
Modular structural frames accept sealed lighting and service openings without breaking the surrounding clean-air surface.
Kunden Produktbedenken
A laminar ceiling must deliver nearly uniform velocity over a large footprint while fitting lights, equipment rails and service penetrations around the protected zone.
Typische Anwendungen
Technische Parameter
Representative construction and size ranges for a modular HEPA-filtered laminar flow ceiling are shown below.
| Core Material | Glass-microfiber H14 HEPA filter packs in aluminum frames with polyurethane or gel seals |
|---|---|
| Panel Dicke | 0.8–1.2 mm plenum panels and 1.0–2.0 mm structural frame sections |
| Effektive Breite | 1800–3500 mm typical protected ceiling width |
| Maximale Länge | Up to 3500 mm in standard modular arrays, with larger custom assemblies |
| Stahl facing Dicke | 0.8–1.2 mm powder-coated or stainless plenum facing |
| Kerndichte | Approximately 8000 kg/m³ for the optional 304 stainless-steel plenum and frame surfaces |
| Thermische Leitfähigkeit | Approximately 14–16 W/(m·K) for the optional 304 stainless-steel plenum and frame surfaces |
| Oberfläche Finish | White powder-coated steel or brushed 304 stainless steel with cleanable diffuser membrane |
| Gemeinsamer Typ | Bolted gasketed ceiling modules with individually sealed HEPA cells and sealed service penetrations |
| Customisierung | Verfügbar je nach beabsichtigter Anwendung und Betriebsumgebung. |
Verfügbare Optionen
Planning a Cleanroom Laminar Flow Ceiling specification?
Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Englisch
DeutschCurrent
Arabisch
Französisch
indonesisch
Japanisch
Koreanisch
Malaiisch
Portugiesisch
Russisch
Spanisch
Thailändisch
Türkischer Sprache
Vietnamesisch