Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Sistemas de distribución de aire para salas limpias

Techo de flujo laminar de sala limpia

A modular ceiling plenum and HEPA filter bank that supplies a broad, uniform low-velocity unidirectional airflow over a protected clean process zone.
  • Full-Surface HEPA Supply
  • Uniform Low-Velocity Airflow
  • Modular Filter Bank
  • Integrated Service and Lighting Zones
Solicite un presupuesto. Browse productos

Introducción del producto

The cleanroom laminar flow ceiling combines a sealed supply plenum, multiple terminal HEPA filters and a continuous perforated or textile diffuser surface above the protected area. Airflow is balanced across several duct inlets and filter cells so the discharge velocity remains even from edge to center. The broad downward field sweeps airborne particles away from an operating table, filling line or open product zone with minimal lateral induction. Bolted modular sections accommodate lighting, service columns and ceiling equipment while maintaining sealed filter and perimeter interfaces.

Características clave

A matrix of terminal HEPA filters spreads resistance across the complete protected ceiling area.

The continuous diffuser membrane or perforated face straightens local filter jets into a low-turbulence downward field.

Separate inlet plenums and balancing points allow edge and center zones to be equalized independently.

Modular structural frames accept sealed lighting and service openings without breaking the surrounding clean-air surface.

Preocupaciones del producto del cliente

A laminar ceiling must deliver nearly uniform velocity over a large footprint while fitting lights, equipment rails and service penetrations around the protected zone.

Center filters receive more air than edge filters, creating an uneven downward field.Multiple balanced inlets and zoned plenum sections distribute pressure across the full filter bank.
Gaps around lights interrupt the clean-air curtain over the critical work area.Flush sealed lighting modules occupy planned structural bays within the continuous diffuser layout.
A damaged filter cannot be isolated without opening a large common plenum.Individual room-side filter retainers and test points allow each cell to be inspected and replaced separately.
A rigid diffuser face is difficult to remove around suspended medical equipment.Modular perforated panels or tensioned textile sections provide local access without dismantling the whole ceiling.

Aplicaciones típicas

Sterile pharmaceutical filling zonesHospital operating roomsAseptic product assemblyOpen process protection in biotechnologyPrecision microelectronics work areas

Parámetros técnicos

Representative construction and size ranges for a modular HEPA-filtered laminar flow ceiling are shown below.

Materiales CoreGlass-microfiber H14 HEPA filter packs in aluminum frames with polyurethane or gel seals
Panel de espesor0.8–1.2 mm plenum panels and 1.0–2.0 mm structural frame sections
Ancho efectivo1800–3500 mm typical protected ceiling width
Longitud máximaUp to 3500 mm in standard modular arrays, with larger custom assemblies
Acero frente a espesor0.8–1.2 mm powder-coated or stainless plenum facing
Densidad CoreApproximately 8000 kg/m³ for the optional 304 stainless-steel plenum and frame surfaces
Conductividad térmicaApproximately 14–16 W/(m·K) for the optional 304 stainless-steel plenum and frame surfaces
Superficie acabadaWhite powder-coated steel or brushed 304 stainless steel with cleanable diffuser membrane
Tipo conjuntoBolted gasketed ceiling modules with individually sealed HEPA cells and sealed service penetrations
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Perforated metal or tensioned textile diffuser surfaceIntegrated sealed LED lighting modulesGel-seal or gasket-seal HEPA cellsGlass perimeter skirts and equipment-rail cutouts

Planning a Cleanroom Laminar Flow Ceiling specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo