A modular ceiling plenum and HEPA filter bank that supplies a broad, uniform low-velocity unidirectional airflow over a protected clean process zone.
  • Full-Surface HEPA Supply
  • Uniform Low-Velocity Airflow
  • Modular Filter Bank
  • Integrated Service and Lighting Zones
見積もりリクエスト 製品案内

商品紹介

The cleanroom laminar flow ceiling combines a sealed supply plenum, multiple terminal HEPA filters and a continuous perforated or textile diffuser surface above the protected area. Airflow is balanced across several duct inlets and filter cells so the discharge velocity remains even from edge to center. The broad downward field sweeps airborne particles away from an operating table, filling line or open product zone with minimal lateral induction. Bolted modular sections accommodate lighting, service columns and ceiling equipment while maintaining sealed filter and perimeter interfaces.

主要な特徴

A matrix of terminal HEPA filters spreads resistance across the complete protected ceiling area.

The continuous diffuser membrane or perforated face straightens local filter jets into a low-turbulence downward field.

Separate inlet plenums and balancing points allow edge and center zones to be equalized independently.

Modular structural frames accept sealed lighting and service openings without breaking the surrounding clean-air surface.

お客様の製品に関する懸念事項

A laminar ceiling must deliver nearly uniform velocity over a large footprint while fitting lights, equipment rails and service penetrations around the protected zone.

Center filters receive more air than edge filters, creating an uneven downward field.Multiple balanced inlets and zoned plenum sections distribute pressure across the full filter bank.
Gaps around lights interrupt the clean-air curtain over the critical work area.Flush sealed lighting modules occupy planned structural bays within the continuous diffuser layout.
A damaged filter cannot be isolated without opening a large common plenum.Individual room-side filter retainers and test points allow each cell to be inspected and replaced separately.
A rigid diffuser face is difficult to remove around suspended medical equipment.Modular perforated panels or tensioned textile sections provide local access without dismantling the whole ceiling.

典型的な用途

Sterile pharmaceutical filling zonesHospital operating roomsAseptic product assemblyOpen process protection in biotechnologyPrecision microelectronics work areas

技術的なパラメータ

Representative construction and size ranges for a modular HEPA-filtered laminar flow ceiling are shown below.

コア材料Glass-microfiber H14 HEPA filter packs in aluminum frames with polyurethane or gel seals
パネルの厚さ0.8–1.2 mm plenum panels and 1.0–2.0 mm structural frame sections
有効幅1800–3500 mm typical protected ceiling width
最大長さUp to 3500 mm in standard modular arrays, with larger custom assemblies
鋼鉄の厚さを直面する0.8–1.2 mm powder-coated or stainless plenum facing
コア密度Approximately 8000 kg/m³ for the optional 304 stainless-steel plenum and frame surfaces
熱伝導率Approximately 14–16 W/(m·K) for the optional 304 stainless-steel plenum and frame surfaces
表面仕上げWhite powder-coated steel or brushed 304 stainless steel with cleanable diffuser membrane
ジョイントタイプBolted gasketed ceiling modules with individually sealed HEPA cells and sealed service penetrations
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

Perforated metal or tensioned textile diffuser surfaceIntegrated sealed LED lighting modulesGel-seal or gasket-seal HEPA cellsGlass perimeter skirts and equipment-rail cutouts