Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Equipamentos de drenagem, higiene e segurança da sala limpa

Detector de calor de sala limpa

A sealed low-profile thermal detector for spaces where aerosols or process conditions make optical smoke sensing unsuitable.
  • Fixed-Temperature or Rate-of-Rise
  • Low-Profile Cleanable Housing
  • Addressable Status Reporting
  • Sealed Ceiling Base
Solicite um orçamento. Browse produtos

Introdução do produto

The cleanroom heat detector monitors ambient temperature with fixed-threshold, rate-of-rise or combined logic. Its smooth polymer head attaches to a gasketed wired base so the visible ceiling interface remains compact. Addressable variants identify the device and report alarm or fault status, while conventional variants connect to zone circuits using the same serviceable head-and-base arrangement.

Características-chave

Selectable thermal logic suits steady or rapidly changing room conditions.

Smooth housing minimizes exposed recesses.

Twist-lock removal leaves wiring secured in the base.

Local LED and remote-indicator terminals simplify status checks.

Preocupações do produto do cliente

Some controlled spaces produce vapor or aerosols that can cause unwanted optical alarms but still require dependable fire detection.

Routine aerosols resemble smoke to an optical chamber.Thermal sensing responds to temperature behavior instead of airborne particles.
A high normal temperature can sit close to a generic alarm point.The detector class and threshold are selected for the actual ambient range.
Ceiling wiring should not be disturbed during head replacement.A removable sensing head connects to a permanently wired base.
Maintenance staff need quick alarm location.Device addressing and visible LED status identify the active detector.

Aplicações típicas

Clean utility roomsProcess support spacesAreas with routine aerosolsControlled electrical rooms

Parâmetros técnicos

Typical housing and mounting values are listed below; thermal class and system compatibility are selected for the protected space.

Material principalFlame-retardant polymer housing with stainless mounting plate and electronic thermistor
Painel de espessura2.0-3.0 mm molded housing wall
Largura efetiva90-130 mm detector diameter
Comprimento máximoUp to 70 mm installed depth
Aço enfrentando espessura0.8-1.2 mm internal stainless mounting plate
Densidade Core1200-1450 kg/m³ for polymer housing
Condutividade térmica0.18-0.30 W/(m·K) for polymer housing
Superfície acabadoSmooth matte white cleanable housing
Tipo conjuntoTwist-lock thermal head on gasketed wired mounting base
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

Fixed-temperature classRate-of-rise logicAddressable isolator baseRemote indicator