클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
클린룸 배수, 위생 및 안전 장비

클린룸 열 탐지기

A sealed low-profile thermal detector for spaces where aerosols or process conditions make optical smoke sensing unsuitable.
  • Fixed-Temperature or Rate-of-Rise
  • Low-Profile Cleanable Housing
  • Addressable Status Reporting
  • Sealed Ceiling Base
견적 요청 제품 찾아보기

상품 소개

The cleanroom heat detector monitors ambient temperature with fixed-threshold, rate-of-rise or combined logic. Its smooth polymer head attaches to a gasketed wired base so the visible ceiling interface remains compact. Addressable variants identify the device and report alarm or fault status, while conventional variants connect to zone circuits using the same serviceable head-and-base arrangement.

주요 기능

Selectable thermal logic suits steady or rapidly changing room conditions.

Smooth housing minimizes exposed recesses.

Twist-lock removal leaves wiring secured in the base.

Local LED and remote-indicator terminals simplify status checks.

고객 제품 관심사

Some controlled spaces produce vapor or aerosols that can cause unwanted optical alarms but still require dependable fire detection.

Routine aerosols resemble smoke to an optical chamber.Thermal sensing responds to temperature behavior instead of airborne particles.
A high normal temperature can sit close to a generic alarm point.The detector class and threshold are selected for the actual ambient range.
Ceiling wiring should not be disturbed during head replacement.A removable sensing head connects to a permanently wired base.
Maintenance staff need quick alarm location.Device addressing and visible LED status identify the active detector.

일반적인 응용 프로그램

Clean utility roomsProcess support spacesAreas with routine aerosolsControlled electrical rooms

기술 매개변수

Typical housing and mounting values are listed below; thermal class and system compatibility are selected for the protected space.

핵심 재료Flame-retardant polymer housing with stainless mounting plate and electronic thermistor
패널 두께2.0-3.0 mm molded housing wall
유효 폭90-130 mm detector diameter
최대 길이Up to 70 mm installed depth
강철 면면 두께0.8-1.2 mm internal stainless mounting plate
코어 밀도1200-1450 kg/m³ for polymer housing
열전도도 (Thermal Conductivity)0.18-0.30 W/(m·K) for polymer housing
표면 마무리Smooth matte white cleanable housing
접합 유형Twist-lock thermal head on gasketed wired mounting base
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

Fixed-temperature classRate-of-rise logicAddressable isolator baseRemote indicator