Ваш универсальный поставщик оборудования для чистых помещений и асептических средствПоддержка международных проектов
Open mobile navigationClose mobile navigation
Дренажное оборудование, оборудование для гигиены и безопасности в чистых помещениях

Тепловой детектор в чистой комнате

A sealed low-profile thermal detector for spaces where aerosols or process conditions make optical smoke sensing unsuitable.
  • Fixed-Temperature or Rate-of-Rise
  • Low-Profile Cleanable Housing
  • Addressable Status Reporting
  • Sealed Ceiling Base
Запрос котировки Просмотреть продукты

Введение продукции

The cleanroom heat detector monitors ambient temperature with fixed-threshold, rate-of-rise or combined logic. Its smooth polymer head attaches to a gasketed wired base so the visible ceiling interface remains compact. Addressable variants identify the device and report alarm or fault status, while conventional variants connect to zone circuits using the same serviceable head-and-base arrangement.

Основные характеристики

Selectable thermal logic suits steady or rapidly changing room conditions.

Smooth housing minimizes exposed recesses.

Twist-lock removal leaves wiring secured in the base.

Local LED and remote-indicator terminals simplify status checks.

Обеспокоенность клиентов продуктами

Some controlled spaces produce vapor or aerosols that can cause unwanted optical alarms but still require dependable fire detection.

Routine aerosols resemble smoke to an optical chamber.Thermal sensing responds to temperature behavior instead of airborne particles.
A high normal temperature can sit close to a generic alarm point.The detector class and threshold are selected for the actual ambient range.
Ceiling wiring should not be disturbed during head replacement.A removable sensing head connects to a permanently wired base.
Maintenance staff need quick alarm location.Device addressing and visible LED status identify the active detector.

Типичные приложения

Clean utility roomsProcess support spacesAreas with routine aerosolsControlled electrical rooms

Технические параметры

Typical housing and mounting values are listed below; thermal class and system compatibility are selected for the protected space.

Основной материалFlame-retardant polymer housing with stainless mounting plate and electronic thermistor
Толщина панели2.0-3.0 mm molded housing wall
эффективная ширина90-130 mm detector diameter
Максимальная длинаUp to 70 mm installed depth
Толщина линий стали0.8-1.2 mm internal stainless mounting plate
Плотность ядра1200-1450 kg/m³ for polymer housing
Теплопроводимость0.18-0.30 W/(m·K) for polymer housing
Поверхностная отделкаSmooth matte white cleanable housing
Объединенный типTwist-lock thermal head on gasketed wired mounting base
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Доступные варианты

Fixed-temperature classRate-of-rise logicAddressable isolator baseRemote indicator

Planning a Cleanroom Heat Detector specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.

Поговорите с нашей командой
Электронная почта WhatsApp WeChat

Главная

Продукция

Новости

О нас

Контакты