Pengesan haba bilik bersih

A sealed low-profile thermal detector for spaces where aerosols or process conditions make optical smoke sensing unsuitable.
  • Fixed-Temperature or Rate-of-Rise
  • Low-Profile Cleanable Housing
  • Addressable Status Reporting
  • Sealed Ceiling Base
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The cleanroom heat detector monitors ambient temperature with fixed-threshold, rate-of-rise or combined logic. Its smooth polymer head attaches to a gasketed wired base so the visible ceiling interface remains compact. Addressable variants identify the device and report alarm or fault status, while conventional variants connect to zone circuits using the same serviceable head-and-base arrangement.

Ciri-ciri Utama

Selectable thermal logic suits steady or rapidly changing room conditions.

Smooth housing minimizes exposed recesses.

Twist-lock removal leaves wiring secured in the base.

Local LED and remote-indicator terminals simplify status checks.

Kebimbangan Produk Pelanggan

Some controlled spaces produce vapor or aerosols that can cause unwanted optical alarms but still require dependable fire detection.

Routine aerosols resemble smoke to an optical chamber.Thermal sensing responds to temperature behavior instead of airborne particles.
A high normal temperature can sit close to a generic alarm point.The detector class and threshold are selected for the actual ambient range.
Ceiling wiring should not be disturbed during head replacement.A removable sensing head connects to a permanently wired base.
Maintenance staff need quick alarm location.Device addressing and visible LED status identify the active detector.

Permohonan yang biasa

Clean utility roomsProcess support spacesAreas with routine aerosolsControlled electrical rooms

Parameter teknikal

Typical housing and mounting values are listed below; thermal class and system compatibility are selected for the protected space.

Bahan TerasFlame-retardant polymer housing with stainless mounting plate and electronic thermistor
Ketebalan Panel2.0-3.0 mm molded housing wall
Lebar berkesan90-130 mm detector diameter
Panjang maksimumUp to 70 mm installed depth
Keluli Menghadapi Ketebalan0.8-1.2 mm internal stainless mounting plate
Ketumpatan teras1200-1450 kg/m³ for polymer housing
Kekonduksian Terma0.18-0.30 W/(m·K) for polymer housing
Kemasan permukaanSmooth matte white cleanable housing
Jenis BersatuTwist-lock thermal head on gasketed wired mounting base
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Fixed-temperature classRate-of-rise logicAddressable isolator baseRemote indicator

Planning a Cleanroom Heat Detector specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami