موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
معدات الصرف الصحي والنظافة والسلامة في الغرف النظيفة

غرفة نظيفة للكشف عن الحرارة

A sealed low-profile thermal detector for spaces where aerosols or process conditions make optical smoke sensing unsuitable.
  • Fixed-Temperature or Rate-of-Rise
  • Low-Profile Cleanable Housing
  • Addressable Status Reporting
  • Sealed Ceiling Base
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The cleanroom heat detector monitors ambient temperature with fixed-threshold, rate-of-rise or combined logic. Its smooth polymer head attaches to a gasketed wired base so the visible ceiling interface remains compact. Addressable variants identify the device and report alarm or fault status, while conventional variants connect to zone circuits using the same serviceable head-and-base arrangement.

الخصائص الرئيسية

Selectable thermal logic suits steady or rapidly changing room conditions.

Smooth housing minimizes exposed recesses.

Twist-lock removal leaves wiring secured in the base.

Local LED and remote-indicator terminals simplify status checks.

مخاوف المنتج للعملاء

Some controlled spaces produce vapor or aerosols that can cause unwanted optical alarms but still require dependable fire detection.

Routine aerosols resemble smoke to an optical chamber.Thermal sensing responds to temperature behavior instead of airborne particles.
A high normal temperature can sit close to a generic alarm point.The detector class and threshold are selected for the actual ambient range.
Ceiling wiring should not be disturbed during head replacement.A removable sensing head connects to a permanently wired base.
Maintenance staff need quick alarm location.Device addressing and visible LED status identify the active detector.

تطبيقات نموذجية

Clean utility roomsProcess support spacesAreas with routine aerosolsControlled electrical rooms

المعلمات الفنية

Typical housing and mounting values are listed below; thermal class and system compatibility are selected for the protected space.

المواد الأساسيةFlame-retardant polymer housing with stainless mounting plate and electronic thermistor
سمك اللوحة2.0-3.0 mm molded housing wall
العرض الفعال90-130 mm detector diameter
الحد الأقصى الطولUp to 70 mm installed depth
الصلب يواجه سمك0.8-1.2 mm internal stainless mounting plate
الكثافة الأساسية1200-1450 kg/m³ for polymer housing
الموصلية الحرارية0.18-0.30 W/(m·K) for polymer housing
إنهاء السطحSmooth matte white cleanable housing
نوع المشتركTwist-lock thermal head on gasketed wired mounting base
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Fixed-temperature classRate-of-rise logicAddressable isolator baseRemote indicator