موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
معدات التدفق والاحتواء الصفائحية

Dual-Operator Laminar Flow Clean Bench

A wide clean bench with a continuous filtered work area that gives two operators independent reach zones without dividing the protected surface.
  • Two Independent Reach Zones
  • Continuous Clean Worktop
  • Wide Uniform Air Supply
  • Split Utility Access
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The dual-operator bench extends the filter, diffuser and worktop across two working positions. Each operator receives a dedicated lighting and utility area while the continuous stainless surface supports shared trays or long assemblies. Internal fan balancing keeps the air supply even across the wider span, and a stiffened front beam limits deflection above the opening. The design is for non-hazardous product-protection work requiring coordinated two-person handling.

الخصائص الرئيسية

A full-width diffuser avoids a weak central zone between the two operator positions.

Separate utility panels reduce hose and cable crossing over shared work.

The continuous stainless worktop supports long assemblies and coordinated transfers.

Dual lighting sections reduce shadows created by two operators working side by side.

A reinforced front beam maintains sash alignment across the wider cabinet opening.

مخاوف المنتج للعملاء

A two-person clean bench must preserve uniform airflow across a wide opening while separating utilities and operator movements.

Air velocity drops at the center of a wide work zone.Balanced fan branches and a continuous diffuser distribute supply across both positions.
Cables from two operators cross the shared process area.Left and right service panels keep utilities within each operator's reach zone.
A jointed worktop interrupts long assemblies.A continuous reinforced stainless surface spans the dual working width.
The long sash rail can sag and bind.A stiffened front structure supports accurate sash travel across the full opening.

تطبيقات نموذجية

Large medical-device assemblyTwo-person sterile set preparationLong optical component handlingCollaborative electronics inspection

المعلمات الفنية

Typical configurable construction ranges for a dual-operator laminar flow clean bench are listed below.

المواد الأساسيةSUS304 continuous work surface with reinforced powder-coated steel enclosure and mineral-wool acoustic infill
سمك اللوحة30-50 mm reinforced double-skin sections
العرض الفعال1500-2400 mm clear working width
الحد الأقصى الطولUp to 2600 mm overall bench width
الصلب يواجه سمك1.0-1.2 ملم الصلب الخارجي؛ 1.2-1.5 ملم SUS304 سطح العمل
الكثافة الأساسية80-120 كجم / م3 الصوف المعدني الصوتية ملء
الموصلية الحرارية0.035-0.045 W/(m·K) for the mineral-wool infill
إنهاء السطحWhite powder-coated enclosure with brushed continuous SUS304 work surface
نوع المشتركReinforced sealed cabinet seams with a full-width filter clamp and continuous worktop support
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Two independent utility panelsMotorized full-width sashDual blower monitoringSit-stand base configuration

Planning a Dual-Operator Laminar Flow Clean Bench specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat

الرئيسية

المنتجات

الأخبار

من نحن

اتصل بنا