Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Ana Sayfa / Ürünler / Temiz Oda HVAC ve Hava İşleme Ekipmanları / Modular Air-Cooled Scroll Chiller
Temiz Oda HVAC ve Hava İşleme Ekipmanları

Modüler Hava Soğutmalı Scroll Soğutucu

An expandable chilled-water system built from parallel air-cooled scroll modules that stage together as cleanroom cooling demand grows.
  • Expandable Parallel Modules
  • Independent Refrigerant Circuits
  • Fine Capacity Staging
  • Serviceable Without Total Shutdown
Alıntı isteği Browse ürünleri

Ürün tanıtımı

The modular air-cooled scroll chiller divides plant capacity among compact factory-built modules connected to common chilled-water headers and a coordinating controller. Each module contains scroll compressors, a liquid heat exchanger, condenser coil and fans. Additional modules increase capacity without replacing the original plant, while multiple compressors provide small operating steps. Isolation valves and independent circuits allow one module to be serviced while the remaining modules continue supplying partial cooling.

Ana Özellikler

Parallel modules allow cooling capacity to expand in planned increments as production demand increases.

Multiple scroll compressors provide small capacity steps and useful low-load turndown.

Independent refrigerant circuits confine a service event to one module rather than the complete plant.

A common controller rotates lead duty and stages modules against leaving-water temperature.

Müşteri Ürün Sorunları

A growing facility needs enough initial cooling without buying an oversized single chiller that will cycle inefficiently for years.

Initial cleanroom load is small but future production phases require more capacity.Additional matched modules connect to the common headers and controller as demand grows.
One chiller failure removes all process cooling.Independent modules continue operating at the remaining available capacity.
Unequal water flow causes some modules to trip while others carry little load.Reverse-return headers, balancing valves and coordinated pump control distribute flow.
Modules accumulate unequal compressor hours.Lead-lag rotation balances starts and run time across the staged plant.

Tipik uygulamalar

Phased cleanroom expansionsSmall pharmaceutical plantsLaboratory campusesMedical-device manufacturingProcess cooling with staged demand

Teknik parametreler

Representative single-module construction and chilled-water insulation data are listed below.

Temel malzemelerRigid polyisocyanurate foam around the brazed-plate evaporator and chilled-water headers
Panel kalınlığı1.0–1.5 mm removable module enclosure panels
Effective Width (Etkili Genişlik)800–1500 mm nominal width per module
Maksimum uzunluk1900–2550 mm per factory module
Çelik yüz yüze kalınlığı1.0–2.0 mm galvanized module frame and service panels
Core Density (Çekirdek Yoğunluğu)32 kg/m³ nominal rigid polyisocyanurate insulation
Termal İletkenlik0.023 W/(m·K) at 10°C for the polyisocyanurate insulation
Yüzey bitirmeOutdoor powder-coated galvanized steel with aluminum-copper or microchannel condenser
Ortak tipBolted modular bases with common grooved water headers and independent isolation valves
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Mevcut Seçenekler

Two to sixteen coordinated modules with common headersIntegrated primary pump and buffer tankLow-ambient and low-noise packagesHeat-pump or cooling-only module configuration