Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Bilik Bersih HVAC dan Peralatan Pengendalian Udara

Modular Air-Cooled Scroll Chiller

An expandable chilled-water system built from parallel air-cooled scroll modules that stage together as cleanroom cooling demand grows.
  • Expandable Parallel Modules
  • Independent Refrigerant Circuits
  • Fine Capacity Staging
  • Serviceable Without Total Shutdown
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The modular air-cooled scroll chiller divides plant capacity among compact factory-built modules connected to common chilled-water headers and a coordinating controller. Each module contains scroll compressors, a liquid heat exchanger, condenser coil and fans. Additional modules increase capacity without replacing the original plant, while multiple compressors provide small operating steps. Isolation valves and independent circuits allow one module to be serviced while the remaining modules continue supplying partial cooling.

Ciri-ciri Utama

Parallel modules allow cooling capacity to expand in planned increments as production demand increases.

Multiple scroll compressors provide small capacity steps and useful low-load turndown.

Independent refrigerant circuits confine a service event to one module rather than the complete plant.

A common controller rotates lead duty and stages modules against leaving-water temperature.

Kebimbangan Produk Pelanggan

A growing facility needs enough initial cooling without buying an oversized single chiller that will cycle inefficiently for years.

Initial cleanroom load is small but future production phases require more capacity.Additional matched modules connect to the common headers and controller as demand grows.
One chiller failure removes all process cooling.Independent modules continue operating at the remaining available capacity.
Unequal water flow causes some modules to trip while others carry little load.Reverse-return headers, balancing valves and coordinated pump control distribute flow.
Modules accumulate unequal compressor hours.Lead-lag rotation balances starts and run time across the staged plant.

Permohonan yang biasa

Phased cleanroom expansionsSmall pharmaceutical plantsLaboratory campusesMedical-device manufacturingProcess cooling with staged demand

Parameter teknikal

Representative single-module construction and chilled-water insulation data are listed below.

Bahan TerasRigid polyisocyanurate foam around the brazed-plate evaporator and chilled-water headers
Ketebalan Panel1.0–1.5 mm removable module enclosure panels
Lebar berkesan800–1500 mm nominal width per module
Panjang maksimum1900–2550 mm per factory module
Keluli Menghadapi Ketebalan1.0–2.0 mm galvanized module frame and service panels
Ketumpatan teras32 kg/m³ nominal rigid polyisocyanurate insulation
Kekonduksian Terma0.023 W/(m·K) at 10°C for the polyisocyanurate insulation
Kemasan permukaanOutdoor powder-coated galvanized steel with aluminum-copper or microchannel condenser
Jenis BersatuBolted modular bases with common grooved water headers and independent isolation valves
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Two to sixteen coordinated modules with common headersIntegrated primary pump and buffer tankLow-ambient and low-noise packagesHeat-pump or cooling-only module configuration

Planning a Modular Air-Cooled Scroll Chiller specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami