Froid à scroll modulaire refroidi par air
- Expandable Parallel Modules
- Independent Refrigerant Circuits
- Fine Capacity Staging
- Serviceable Without Total Shutdown
Introduction de produit
The modular air-cooled scroll chiller divides plant capacity among compact factory-built modules connected to common chilled-water headers and a coordinating controller. Each module contains scroll compressors, a liquid heat exchanger, condenser coil and fans. Additional modules increase capacity without replacing the original plant, while multiple compressors provide small operating steps. Isolation valves and independent circuits allow one module to be serviced while the remaining modules continue supplying partial cooling.
Key Features
Multiple scroll compressors provide small capacity steps and useful low-load turndown.
Independent refrigerant circuits confine a service event to one module rather than the complete plant.
A common controller rotates lead duty and stages modules against leaving-water temperature.
Préoccupations du client produit
A growing facility needs enough initial cooling without buying an oversized single chiller that will cycle inefficiently for years.
Les applications typiques
Paramètres techniques
Representative single-module construction and chilled-water insulation data are listed below.
| Matériaux de base | Rigid polyisocyanurate foam around the brazed-plate evaporator and chilled-water headers |
|---|---|
| Panneau épaisseur | 1.0–1.5 mm removable module enclosure panels |
| Largeur effective | 800–1500 mm nominal width per module |
| Longueur maximale | 1900–2550 mm per factory module |
| Acier face épaisseur | 1.0–2.0 mm galvanized module frame and service panels |
| Densité Core | 32 kg/m³ nominal rigid polyisocyanurate insulation |
| Conductivité thermique | 0.023 W/(m·K) at 10°C for the polyisocyanurate insulation |
| surface finie | Outdoor powder-coated galvanized steel with aluminum-copper or microchannel condenser |
| Type joint | Bolted modular bases with common grooved water headers and independent isolation valves |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Modular Air-Cooled Scroll Chiller specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.