Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Equipos de HVAC y manejo de aire para salas limpias

Modular refrigerado por aire scroll chiller

An expandable chilled-water system built from parallel air-cooled scroll modules that stage together as cleanroom cooling demand grows.
  • Expandable Parallel Modules
  • Independent Refrigerant Circuits
  • Fine Capacity Staging
  • Serviceable Without Total Shutdown
Solicite un presupuesto. Browse productos

Introducción del producto

The modular air-cooled scroll chiller divides plant capacity among compact factory-built modules connected to common chilled-water headers and a coordinating controller. Each module contains scroll compressors, a liquid heat exchanger, condenser coil and fans. Additional modules increase capacity without replacing the original plant, while multiple compressors provide small operating steps. Isolation valves and independent circuits allow one module to be serviced while the remaining modules continue supplying partial cooling.

Características clave

Parallel modules allow cooling capacity to expand in planned increments as production demand increases.

Multiple scroll compressors provide small capacity steps and useful low-load turndown.

Independent refrigerant circuits confine a service event to one module rather than the complete plant.

A common controller rotates lead duty and stages modules against leaving-water temperature.

Preocupaciones del producto del cliente

A growing facility needs enough initial cooling without buying an oversized single chiller that will cycle inefficiently for years.

Initial cleanroom load is small but future production phases require more capacity.Additional matched modules connect to the common headers and controller as demand grows.
One chiller failure removes all process cooling.Independent modules continue operating at the remaining available capacity.
Unequal water flow causes some modules to trip while others carry little load.Reverse-return headers, balancing valves and coordinated pump control distribute flow.
Modules accumulate unequal compressor hours.Lead-lag rotation balances starts and run time across the staged plant.

Aplicaciones típicas

Phased cleanroom expansionsSmall pharmaceutical plantsLaboratory campusesFabricación de dispositivos médicosProcess cooling with staged demand

Parámetros técnicos

Representative single-module construction and chilled-water insulation data are listed below.

Materiales CoreRigid polyisocyanurate foam around the brazed-plate evaporator and chilled-water headers
Panel de espesor1.0–1.5 mm removable module enclosure panels
Ancho efectivo800–1500 mm nominal width per module
Longitud máxima1900–2550 mm per factory module
Acero frente a espesor1.0–2.0 mm galvanized module frame and service panels
Densidad Core32 kg/m³ nominal rigid polyisocyanurate insulation
Conductividad térmica0.023 W/(m·K) at 10°C for the polyisocyanurate insulation
Superficie acabadaOutdoor powder-coated galvanized steel with aluminum-copper or microchannel condenser
Tipo conjuntoBolted modular bases with common grooved water headers and independent isolation valves
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Two to sixteen coordinated modules with common headersIntegrated primary pump and buffer tankLow-ambient and low-noise packagesHeat-pump or cooling-only module configuration

Planning a Modular Air-Cooled Scroll Chiller specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat