Pemasok One-Stop Anda untuk Peralatan Cleanroom dan Fasilitas Aseptik EsensialDukungan proyek internasional
Open mobile navigationClose mobile navigation
Beranda / Produk / Cleanroom HVAC dan Peralatan Penanganan Udara / Modular Air-Cooled Scroll Chiller
Cleanroom HVAC dan Peralatan Penanganan Udara

Modular Air-Cooled Scroll Chiller

An expandable chilled-water system built from parallel air-cooled scroll modules that stage together as cleanroom cooling demand grows.
  • Expandable Parallel Modules
  • Independent Refrigerant Circuits
  • Fine Capacity Staging
  • Serviceable Without Total Shutdown
Permintaan untuk kutipan Browse Produk

Perkenalan produk

The modular air-cooled scroll chiller divides plant capacity among compact factory-built modules connected to common chilled-water headers and a coordinating controller. Each module contains scroll compressors, a liquid heat exchanger, condenser coil and fans. Additional modules increase capacity without replacing the original plant, while multiple compressors provide small operating steps. Isolation valves and independent circuits allow one module to be serviced while the remaining modules continue supplying partial cooling.

Fitur utama:

Parallel modules allow cooling capacity to expand in planned increments as production demand increases.

Multiple scroll compressors provide small capacity steps and useful low-load turndown.

Independent refrigerant circuits confine a service event to one module rather than the complete plant.

A common controller rotates lead duty and stages modules against leaving-water temperature.

Kekhawatiran produk pelanggan

A growing facility needs enough initial cooling without buying an oversized single chiller that will cycle inefficiently for years.

Initial cleanroom load is small but future production phases require more capacity.Additional matched modules connect to the common headers and controller as demand grows.
One chiller failure removes all process cooling.Independent modules continue operating at the remaining available capacity.
Unequal water flow causes some modules to trip while others carry little load.Reverse-return headers, balancing valves and coordinated pump control distribute flow.
Modules accumulate unequal compressor hours.Lead-lag rotation balances starts and run time across the staged plant.

Aplikasi yang Tipis

Phased cleanroom expansionsSmall pharmaceutical plantsLaboratory campusesManufaktur Perangkat MedisProcess cooling with staged demand

Parameter teknis

Representative single-module construction and chilled-water insulation data are listed below.

Bahan intiRigid polyisocyanurate foam around the brazed-plate evaporator and chilled-water headers
Ketebalan Panel (Panel Thickness)1.0–1.5 mm removable module enclosure panels
Efektif lebar800–1500 mm nominal width per module
Panjang maksimum1900–2550 mm per factory module
Baja menghadap ketebalan1.0–2.0 mm galvanized module frame and service panels
Kepadatan inti (core density)32 kg/m³ nominal rigid polyisocyanurate insulation
Konduktivitas Termal (Thermal Conductivity)0.023 W/(m·K) at 10°C for the polyisocyanurate insulation
Permukaan selesaiOutdoor powder-coated galvanized steel with aluminum-copper or microchannel condenser
Jenis BersamaBolted modular bases with common grooved water headers and independent isolation valves
Customization (Kustomisasi)Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi.

Pilihan yang tersedia

Two to sixteen coordinated modules with common headersIntegrated primary pump and buffer tankLow-ambient and low-noise packagesHeat-pump or cooling-only module configuration

Planning a Modular Air-Cooled Scroll Chiller specification?

Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bicaralah dengan tim kami
Email Kami WhatsApp WhatsApp WhatsApp WhatsApp WeChat adalah

Beranda

Produk

Berita

Tentang Kami

Hubungi Kami