Damper de incêndio dinâmico
- Spring-Driven Dynamic Closure
- Interlocking Curtain Blades
- Thermal Release Mechanism
- Compact Sleeve Installation
Introdução do produto
The dynamic fire damper stores a folded stack of interlocking galvanized blades outside the normal airway. Under ordinary ventilation the curtain is held open by a thermal release. When released, stainless closure springs draw the blade stack across the opening and lock the interlocking folds into the guide channels. A factory sleeve and retaining-angle arrangement positions the damper at the wall or floor penetration while leaving access to the release and blade track for periodic inspection.
Características-chave
Interlocking galvanized blade folds form a continuous closure across the opening after release.
The open blade stack remains outside the clear airway to minimize normal pressure drop.
Sleeve, retaining-angle and access options adapt the damper to common wall and floor penetration details.
Preocupações do produto do cliente
A fire damper must be installed square at the protected penetration, retain unobstructed curtain travel and keep its thermal release accessible for inspection.
Aplicações típicas
Parâmetros técnicos
Representative construction ranges for a rectangular spring-assisted curtain fire damper are shown below.
| Material principal | Interlocking galvanized-steel curtain blades with stainless closure springs and thermal release |
|---|---|
| Painel de espessura | 0.7–1.0 mm formed interlocking curtain blade sheet |
| Largura efetiva | 152–914 mm nominal single-section clear opening width |
| Comprimento máximo | Up to 1219 mm nominal single-section opening height |
| Aço enfrentando espessura | 1.2–1.5 mm galvanized sleeve, frame and retaining components |
| Densidade Core | Approximately 7850 kg/m³ for the steel curtain blades |
| Condutividade térmica | Approximately 45–55 W/(m·K) for galvanized carbon steel |
| Superfície acabado | Mill-galvanized curtain, sleeve and frame with corrosion-resistant spring hardware |
| Tipo conjunto | Sleeved penetration frame with spring-driven interlocking curtain, side tracks and thermal release |
| Customização | Disponível com base na aplicação pretendida e no ambiente operacional. |
Opções disponíveis
Planning a Dynamic Fire Damper specification?
Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Inglês
Alemão
Língua árabe
Francês
Língua indonésia
Japonês
Coreano
Língua malaia
Portuguêsatual
Língua russa
Espanhol
Tailandês
Língua turca
Vietnã