Dynamischer Branddämpfer
- Spring-Driven Dynamic Closure
- Interlocking Curtain Blades
- Thermal Release Mechanism
- Compact Sleeve Installation
Produkteinführung
The dynamic fire damper stores a folded stack of interlocking galvanized blades outside the normal airway. Under ordinary ventilation the curtain is held open by a thermal release. When released, stainless closure springs draw the blade stack across the opening and lock the interlocking folds into the guide channels. A factory sleeve and retaining-angle arrangement positions the damper at the wall or floor penetration while leaving access to the release and blade track for periodic inspection.
Key Features
Interlocking galvanized blade folds form a continuous closure across the opening after release.
The open blade stack remains outside the clear airway to minimize normal pressure drop.
Sleeve, retaining-angle and access options adapt the damper to common wall and floor penetration details.
Kunden Produktbedenken
A fire damper must be installed square at the protected penetration, retain unobstructed curtain travel and keep its thermal release accessible for inspection.
Typische Anwendungen
Technische Parameter
Representative construction ranges for a rectangular spring-assisted curtain fire damper are shown below.
| Core Material | Interlocking galvanized-steel curtain blades with stainless closure springs and thermal release |
|---|---|
| Panel Dicke | 0.7–1.0 mm formed interlocking curtain blade sheet |
| Effektive Breite | 152–914 mm nominal single-section clear opening width |
| Maximale Länge | Up to 1219 mm nominal single-section opening height |
| Stahl facing Dicke | 1.2–1.5 mm galvanized sleeve, frame and retaining components |
| Kerndichte | Approximately 7850 kg/m³ for the steel curtain blades |
| Thermische Leitfähigkeit | Approximately 45–55 W/(m·K) for galvanized carbon steel |
| Oberfläche Finish | Mill-galvanized curtain, sleeve and frame with corrosion-resistant spring hardware |
| Gemeinsamer Typ | Sleeved penetration frame with spring-driven interlocking curtain, side tracks and thermal release |
| Customisierung | Verfügbar je nach beabsichtigter Anwendung und Betriebsumgebung. |
Verfügbare Optionen
Planning a Dynamic Fire Damper specification?
Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Englisch
DeutschCurrent
Arabisch
Französisch
indonesisch
Japanisch
Koreanisch
Malaiisch
Portugiesisch
Russisch
Spanisch
Thailändisch
Türkischer Sprache
Vietnamesisch