Dinamik Yangın Damper
- Spring-Driven Dynamic Closure
- Interlocking Curtain Blades
- Thermal Release Mechanism
- Compact Sleeve Installation
Ürün tanıtımı
The dynamic fire damper stores a folded stack of interlocking galvanized blades outside the normal airway. Under ordinary ventilation the curtain is held open by a thermal release. When released, stainless closure springs draw the blade stack across the opening and lock the interlocking folds into the guide channels. A factory sleeve and retaining-angle arrangement positions the damper at the wall or floor penetration while leaving access to the release and blade track for periodic inspection.
Ana Özellikler
Interlocking galvanized blade folds form a continuous closure across the opening after release.
The open blade stack remains outside the clear airway to minimize normal pressure drop.
Sleeve, retaining-angle and access options adapt the damper to common wall and floor penetration details.
Müşteri Ürün Sorunları
A fire damper must be installed square at the protected penetration, retain unobstructed curtain travel and keep its thermal release accessible for inspection.
Tipik uygulamalar
Teknik parametreler
Representative construction ranges for a rectangular spring-assisted curtain fire damper are shown below.
| Temel malzemeler | Interlocking galvanized-steel curtain blades with stainless closure springs and thermal release |
|---|---|
| Panel kalınlığı | 0.7–1.0 mm formed interlocking curtain blade sheet |
| Effective Width (Etkili Genişlik) | 152–914 mm nominal single-section clear opening width |
| Maksimum uzunluk | Up to 1219 mm nominal single-section opening height |
| Çelik yüz yüze kalınlığı | 1.2–1.5 mm galvanized sleeve, frame and retaining components |
| Core Density (Çekirdek Yoğunluğu) | Approximately 7850 kg/m³ for the steel curtain blades |
| Termal İletkenlik | Approximately 45–55 W/(m·K) for galvanized carbon steel |
| Yüzey bitirme | Mill-galvanized curtain, sleeve and frame with corrosion-resistant spring hardware |
| Ortak tip | Sleeved penetration frame with spring-driven interlocking curtain, side tracks and thermal release |
| Customization (Özelleşme) | Kullanılan uygulama ve çalışma ortamına göre kullanılabilir. |
Mevcut Seçenekler
Planning a Dynamic Fire Damper specification?
Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

İngilizce
Almanca
Arapça
Fransızca
Endonezya dilinde
Japonca
Korece
Malay dilinde
Portekizce
Rusça
İspanyolca
Taylandca
TürkçeCurrent
Vietnamca