Amortisseur d'incendie dynamique
- Spring-Driven Dynamic Closure
- Interlocking Curtain Blades
- Thermal Release Mechanism
- Compact Sleeve Installation
Introduction de produit
The dynamic fire damper stores a folded stack of interlocking galvanized blades outside the normal airway. Under ordinary ventilation the curtain is held open by a thermal release. When released, stainless closure springs draw the blade stack across the opening and lock the interlocking folds into the guide channels. A factory sleeve and retaining-angle arrangement positions the damper at the wall or floor penetration while leaving access to the release and blade track for periodic inspection.
Key Features
Interlocking galvanized blade folds form a continuous closure across the opening after release.
The open blade stack remains outside the clear airway to minimize normal pressure drop.
Sleeve, retaining-angle and access options adapt the damper to common wall and floor penetration details.
Préoccupations du client produit
A fire damper must be installed square at the protected penetration, retain unobstructed curtain travel and keep its thermal release accessible for inspection.
Les applications typiques
Paramètres techniques
Representative construction ranges for a rectangular spring-assisted curtain fire damper are shown below.
| Matériaux de base | Interlocking galvanized-steel curtain blades with stainless closure springs and thermal release |
|---|---|
| Panneau épaisseur | 0.7–1.0 mm formed interlocking curtain blade sheet |
| Largeur effective | 152–914 mm nominal single-section clear opening width |
| Longueur maximale | Up to 1219 mm nominal single-section opening height |
| Acier face épaisseur | 1.2–1.5 mm galvanized sleeve, frame and retaining components |
| Densité Core | Approximately 7850 kg/m³ for the steel curtain blades |
| Conductivité thermique | Approximately 45–55 W/(m·K) for galvanized carbon steel |
| surface finie | Mill-galvanized curtain, sleeve and frame with corrosion-resistant spring hardware |
| Type joint | Sleeved penetration frame with spring-driven interlocking curtain, side tracks and thermal release |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Dynamic Fire Damper specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc
Le vietnamien