Gabinete de Segurança Biológica Classe II Tipo B2
- 100 Percent Total Exhaust
- Hard-Duct Building Connection
- HEPA-Filtered Supply Downflow
- Exhaust Interlock Monitoring
Introdução do produto
The Type B2 cabinet combines inward face airflow with filtered vertical downflow, then sends the entire cabinet air volume to a dedicated building exhaust system. No work-zone air is recirculated within the cabinet. The supply blower and facility exhaust must remain balanced, and an exhaust-loss interlock warns or stops cabinet operation if the external system fails. The configuration can support biological work involving limited evaluated volatile chemicals when the complete installation and procedure are suitable.
Características-chave
A dedicated supply HEPA stage provides clean vertical air over the product.
Exhaust-loss monitoring protects the inward containment boundary.
Negative-pressure plenums enclose contaminated internal air paths.
A serviceable exhaust transition coordinates the cabinet with building ductwork.
Preocupações do produto do cliente
A B2 cabinet depends on the building exhaust system, so cabinet airflow, room balance and duct performance must operate together.
Aplicações típicas
Parâmetros técnicos
Typical configurable construction ranges for a Class II Type B2 biological safety cabinet are listed below.
| Material principal | SUS316L work-zone liner with powder-coated steel outer shell and mineral-wool insulated supply and exhaust plenums |
|---|---|
| Painel de espessura | 40-75 mm double-skin supply and exhaust sections |
| Largura efetiva | 1200-1800 mm clear working width |
| Comprimento máximo | Up to 2600 mm overall cabinet height including exhaust transition |
| Aço enfrentando espessura | 1.2-1.5 mm SUS316L inner liner; 1.0-1.2 mm outer steel |
| Densidade Core | 100-140 kg/m³ mineral-wool plenum insulation |
| Condutividade térmica | 0.035-0.045 W/(m·K) for the mineral-wool insulation |
| Superfície acabado | Fine-brushed SUS316L work zone with sealed white powder-coated exterior |
| Tipo conjunto | Welded negative-pressure inner plenums with gasketed HEPA frames and flanged hard-duct exhaust transition |
| Customização | Disponível com base na aplicação pretendida e no ambiente operacional. |
Opções disponíveis
Planning a Class II Type B2 Biological Safety Cabinet specification?
Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Inglês
Alemão
Língua árabe
Francês
Língua indonésia
Japonês
Coreano
Língua malaia
Portuguêsatual
Língua russa
Espanhol
Tailandês
Língua turca
Vietnã