Cabinet de sécurité biologique de classe II de type B2
- 100 Percent Total Exhaust
- Hard-Duct Building Connection
- HEPA-Filtered Supply Downflow
- Exhaust Interlock Monitoring
Introduction de produit
The Type B2 cabinet combines inward face airflow with filtered vertical downflow, then sends the entire cabinet air volume to a dedicated building exhaust system. No work-zone air is recirculated within the cabinet. The supply blower and facility exhaust must remain balanced, and an exhaust-loss interlock warns or stops cabinet operation if the external system fails. The configuration can support biological work involving limited evaluated volatile chemicals when the complete installation and procedure are suitable.
Key Features
A dedicated supply HEPA stage provides clean vertical air over the product.
Exhaust-loss monitoring protects the inward containment boundary.
Negative-pressure plenums enclose contaminated internal air paths.
A serviceable exhaust transition coordinates the cabinet with building ductwork.
Préoccupations du client produit
A B2 cabinet depends on the building exhaust system, so cabinet airflow, room balance and duct performance must operate together.
Les applications typiques
Paramètres techniques
Typical configurable construction ranges for a Class II Type B2 biological safety cabinet are listed below.
| Matériaux de base | SUS316L work-zone liner with powder-coated steel outer shell and mineral-wool insulated supply and exhaust plenums |
|---|---|
| Panneau épaisseur | 40-75 mm double-skin supply and exhaust sections |
| Largeur effective | 1200-1800 mm clear working width |
| Longueur maximale | Up to 2600 mm overall cabinet height including exhaust transition |
| Acier face épaisseur | 1.2-1.5 mm SUS316L inner liner; 1.0-1.2 mm outer steel |
| Densité Core | 100-140 kg/m³ mineral-wool plenum insulation |
| Conductivité thermique | 0.035-0.045 W/(m·K) for the mineral-wool insulation |
| surface finie | Fine-brushed SUS316L work zone with sealed white powder-coated exterior |
| Type joint | Welded negative-pressure inner plenums with gasketed HEPA frames and flanged hard-duct exhaust transition |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Class II Type B2 Biological Safety Cabinet specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc
Le vietnamien