Kelas II Jenis B2 Kabinet Keselamatan Biologi
- 100 Percent Total Exhaust
- Hard-Duct Building Connection
- HEPA-Filtered Supply Downflow
- Exhaust Interlock Monitoring
Pengenalan Produk
The Type B2 cabinet combines inward face airflow with filtered vertical downflow, then sends the entire cabinet air volume to a dedicated building exhaust system. No work-zone air is recirculated within the cabinet. The supply blower and facility exhaust must remain balanced, and an exhaust-loss interlock warns or stops cabinet operation if the external system fails. The configuration can support biological work involving limited evaluated volatile chemicals when the complete installation and procedure are suitable.
Ciri-ciri Utama
A dedicated supply HEPA stage provides clean vertical air over the product.
Exhaust-loss monitoring protects the inward containment boundary.
Negative-pressure plenums enclose contaminated internal air paths.
A serviceable exhaust transition coordinates the cabinet with building ductwork.
Kebimbangan Produk Pelanggan
A B2 cabinet depends on the building exhaust system, so cabinet airflow, room balance and duct performance must operate together.
Permohonan yang biasa
Parameter teknikal
Typical configurable construction ranges for a Class II Type B2 biological safety cabinet are listed below.
| Bahan Teras | SUS316L work-zone liner with powder-coated steel outer shell and mineral-wool insulated supply and exhaust plenums |
|---|---|
| Ketebalan Panel | 40-75 mm double-skin supply and exhaust sections |
| Lebar berkesan | 1200-1800 mm clear working width |
| Panjang maksimum | Up to 2600 mm overall cabinet height including exhaust transition |
| Keluli Menghadapi Ketebalan | 1.2-1.5 mm SUS316L inner liner; 1.0-1.2 mm outer steel |
| Ketumpatan teras | 100-140 kg/m³ mineral-wool plenum insulation |
| Kekonduksian Terma | 0.035-0.045 W/(m·K) for the mineral-wool insulation |
| Kemasan permukaan | Fine-brushed SUS316L work zone with sealed white powder-coated exterior |
| Jenis Bersatu | Welded negative-pressure inner plenums with gasketed HEPA frames and flanged hard-duct exhaust transition |
| Penyesuaian | Boleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi. |
Pilihan yang boleh didapati
Planning a Class II Type B2 Biological Safety Cabinet specification?
Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Bahasa Inggeris
Bahasa Jerman
Bahasa Arab (Bahasa Melayu)
Bahasa Perancis
Bahasa Indonesia: Bahasa Indonesia
Bahasa Jepun
Bahasa Korea (Bahasa Melayu)
Bahasa Melayu (Bahasa Melayu)Semasa
Bahasa Portugis: Bahasa Portugis: Bahasa Portugis
Bahasa Rusia
Bahasa Sepanyol: Bahasa Sepanyol: Bahasa Sepanyol
Bahasa Melayu (Bahasa Melayu)
Bahasa Turki: Bahasa Turki
Bahasa Vietnam (Bahasa Melayu)