Kabinet Keamanan Biologi Kelas II Tipe B2
- 100 Percent Total Exhaust
- Hard-Duct Building Connection
- HEPA-Filtered Supply Downflow
- Exhaust Interlock Monitoring
Perkenalan produk
The Type B2 cabinet combines inward face airflow with filtered vertical downflow, then sends the entire cabinet air volume to a dedicated building exhaust system. No work-zone air is recirculated within the cabinet. The supply blower and facility exhaust must remain balanced, and an exhaust-loss interlock warns or stops cabinet operation if the external system fails. The configuration can support biological work involving limited evaluated volatile chemicals when the complete installation and procedure are suitable.
Fitur utama:
A dedicated supply HEPA stage provides clean vertical air over the product.
Exhaust-loss monitoring protects the inward containment boundary.
Negative-pressure plenums enclose contaminated internal air paths.
A serviceable exhaust transition coordinates the cabinet with building ductwork.
Kekhawatiran produk pelanggan
A B2 cabinet depends on the building exhaust system, so cabinet airflow, room balance and duct performance must operate together.
Aplikasi yang Tipis
Parameter teknis
Typical configurable construction ranges for a Class II Type B2 biological safety cabinet are listed below.
| Bahan inti | SUS316L work-zone liner with powder-coated steel outer shell and mineral-wool insulated supply and exhaust plenums |
|---|---|
| Ketebalan Panel (Panel Thickness) | 40-75 mm double-skin supply and exhaust sections |
| Efektif lebar | 1200-1800 mm clear working width |
| Panjang maksimum | Up to 2600 mm overall cabinet height including exhaust transition |
| Baja menghadap ketebalan | 1.2-1.5 mm SUS316L inner liner; 1.0-1.2 mm outer steel |
| Kepadatan inti (core density) | 100-140 kg/m³ mineral-wool plenum insulation |
| Konduktivitas Termal (Thermal Conductivity) | 0.035-0.045 W/(m·K) for the mineral-wool insulation |
| Permukaan selesai | Fine-brushed SUS316L work zone with sealed white powder-coated exterior |
| Jenis Bersama | Welded negative-pressure inner plenums with gasketed HEPA frames and flanged hard-duct exhaust transition |
| Customization (Kustomisasi) | Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi. |
Pilihan yang tersedia
Planning a Class II Type B2 Biological Safety Cabinet specification?
Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.