ホーム / 製品 / 層流 · 封じ込め装置 / Class II Type B2 Biological Safety Cabinet
層流 · 封じ込め装置

Class II タイプ B2 生物安全キャビネット

A total-exhaust Class II cabinet that sends all work-zone air through a dedicated building exhaust connection without recirculating it inside the cabinet.
  • 100 Percent Total Exhaust
  • Hard-Duct Building Connection
  • HEPA-Filtered Supply Downflow
  • Exhaust Interlock Monitoring
見積もりリクエスト 製品案内

商品紹介

The Type B2 cabinet combines inward face airflow with filtered vertical downflow, then sends the entire cabinet air volume to a dedicated building exhaust system. No work-zone air is recirculated within the cabinet. The supply blower and facility exhaust must remain balanced, and an exhaust-loss interlock warns or stops cabinet operation if the external system fails. The configuration can support biological work involving limited evaluated volatile chemicals when the complete installation and procedure are suitable.

主要な特徴

All work-zone air leaves through the hard-ducted exhaust connection.

A dedicated supply HEPA stage provides clean vertical air over the product.

Exhaust-loss monitoring protects the inward containment boundary.

Negative-pressure plenums enclose contaminated internal air paths.

A serviceable exhaust transition coordinates the cabinet with building ductwork.

お客様の製品に関する懸念事項

A B2 cabinet depends on the building exhaust system, so cabinet airflow, room balance and duct performance must operate together.

Exhaust failure reverses or weakens face containment.An exhaust interlock alarms and can disable the cabinet supply when duct flow is lost.
Building airflow changes disturb cabinet balance.A coordinated exhaust valve and pressure sensing stabilize the cabinet connection.
Heat and conditioned air are continuously exhausted.Efficient EC blowers and correctly sized duct control reduce avoidable energy demand.
Users assume any chemical quantity is acceptable.The application is limited to substances and quantities evaluated for the complete exhaust installation.

典型的な用途

Biological work with evaluated volatile chemical useToxicological studiesPharmaceutical microbiology requiring total exhaustSpecialized clinical laboratory procedures

技術的なパラメータ

Typical configurable construction ranges for a Class II Type B2 biological safety cabinet are listed below.

コア材料SUS316L work-zone liner with powder-coated steel outer shell and mineral-wool insulated supply and exhaust plenums
パネルの厚さ40-75 mm double-skin supply and exhaust sections
有効幅1200-1800 mm clear working width
最大長さUp to 2600 mm overall cabinet height including exhaust transition
鋼鉄の厚さを直面する1.2-1.5 mm SUS316L inner liner; 1.0-1.2 mm outer steel
コア密度100 — 140 kg / m3 ミネラルウールプレネム絶縁材
熱伝導率ミネラルウール断熱材の 0.035 — 0.045 W / ( m · K )
表面仕上げFine-brushed SUS316L work zone with sealed white powder-coated exterior
ジョイントタイプWelded negative-pressure inner plenums with gasketed HEPA frames and flanged hard-duct exhaust transition
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

1200 or 1800 mm work widthモーター付きサッシュBuilding exhaust control valveSUS304 or SUS316L work zone