Gabinete de Seguridad Biológica Clase II Tipo B2
- 100 Percent Total Exhaust
- Hard-Duct Building Connection
- HEPA-Filtered Supply Downflow
- Exhaust Interlock Monitoring
Introducción del producto
The Type B2 cabinet combines inward face airflow with filtered vertical downflow, then sends the entire cabinet air volume to a dedicated building exhaust system. No work-zone air is recirculated within the cabinet. The supply blower and facility exhaust must remain balanced, and an exhaust-loss interlock warns or stops cabinet operation if the external system fails. The configuration can support biological work involving limited evaluated volatile chemicals when the complete installation and procedure are suitable.
Características clave
A dedicated supply HEPA stage provides clean vertical air over the product.
Exhaust-loss monitoring protects the inward containment boundary.
Negative-pressure plenums enclose contaminated internal air paths.
A serviceable exhaust transition coordinates the cabinet with building ductwork.
Preocupaciones del producto del cliente
A B2 cabinet depends on the building exhaust system, so cabinet airflow, room balance and duct performance must operate together.
Aplicaciones típicas
Parámetros técnicos
Typical configurable construction ranges for a Class II Type B2 biological safety cabinet are listed below.
| Materiales Core | SUS316L work-zone liner with powder-coated steel outer shell and mineral-wool insulated supply and exhaust plenums |
|---|---|
| Panel de espesor | 40-75 mm double-skin supply and exhaust sections |
| Ancho efectivo | 1200-1800 mm clear working width |
| Longitud máxima | Up to 2600 mm overall cabinet height including exhaust transition |
| Acero frente a espesor | 1.2-1.5 mm SUS316L inner liner; 1.0-1.2 mm outer steel |
| Densidad Core | 100-140 kg/m³ mineral-wool plenum insulation |
| Conductividad térmica | 0.035-0.045 W/(m·K) for the mineral-wool insulation |
| Superficie acabada | Fine-brushed SUS316L work zone with sealed white powder-coated exterior |
| Tipo conjunto | Welded negative-pressure inner plenums with gasketed HEPA frames and flanged hard-duct exhaust transition |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
Planning a Class II Type B2 Biological Safety Cabinet specification?
Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Inglés
Alemán
El árabe
Francés
Idioma indonesio
El japonés
Coreano
El malayo
El portugués
El ruso
EspañolCurrent
Tailandés
El turco
El vietnamita