Klasse II Typ B2 Biologische Sicherheit Schrank
- 100 Percent Total Exhaust
- Hard-Duct Building Connection
- HEPA-Filtered Supply Downflow
- Exhaust Interlock Monitoring
Produkteinführung
The Type B2 cabinet combines inward face airflow with filtered vertical downflow, then sends the entire cabinet air volume to a dedicated building exhaust system. No work-zone air is recirculated within the cabinet. The supply blower and facility exhaust must remain balanced, and an exhaust-loss interlock warns or stops cabinet operation if the external system fails. The configuration can support biological work involving limited evaluated volatile chemicals when the complete installation and procedure are suitable.
Key Features
A dedicated supply HEPA stage provides clean vertical air over the product.
Exhaust-loss monitoring protects the inward containment boundary.
Negative-pressure plenums enclose contaminated internal air paths.
A serviceable exhaust transition coordinates the cabinet with building ductwork.
Kunden Produktbedenken
A B2 cabinet depends on the building exhaust system, so cabinet airflow, room balance and duct performance must operate together.
Typische Anwendungen
Technische Parameter
Typical configurable construction ranges for a Class II Type B2 biological safety cabinet are listed below.
| Core Material | SUS316L work-zone liner with powder-coated steel outer shell and mineral-wool insulated supply and exhaust plenums |
|---|---|
| Panel Dicke | 40-75 mm double-skin supply and exhaust sections |
| Effektive Breite | 1200-1800 mm clear working width |
| Maximale Länge | Up to 2600 mm overall cabinet height including exhaust transition |
| Stahl facing Dicke | 1.2-1.5 mm SUS316L inner liner; 1.0-1.2 mm outer steel |
| Kerndichte | 100-140 kg/m³ mineral-wool plenum insulation |
| Thermische Leitfähigkeit | 0.035-0.045 W/(m·K) for the mineral-wool insulation |
| Oberfläche Finish | Fine-brushed SUS316L work zone with sealed white powder-coated exterior |
| Gemeinsamer Typ | Welded negative-pressure inner plenums with gasketed HEPA frames and flanged hard-duct exhaust transition |
| Customisierung | Verfügbar je nach beabsichtigter Anwendung und Betriebsumgebung. |
Verfügbare Optionen
Planning a Class II Type B2 Biological Safety Cabinet specification?
Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.