Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Ana Sayfa / Ürünler / Laminar Flow ve Containment Equipment / Class II Type B2 Biological Safety Cabinet
Laminar Flow ve Containment Equipment

Sınıf II Tip B2 Biyolojik Güvenlik Kabine

A total-exhaust Class II cabinet that sends all work-zone air through a dedicated building exhaust connection without recirculating it inside the cabinet.
  • 100 Percent Total Exhaust
  • Hard-Duct Building Connection
  • HEPA-Filtered Supply Downflow
  • Exhaust Interlock Monitoring
Alıntı isteği Browse ürünleri

Ürün tanıtımı

The Type B2 cabinet combines inward face airflow with filtered vertical downflow, then sends the entire cabinet air volume to a dedicated building exhaust system. No work-zone air is recirculated within the cabinet. The supply blower and facility exhaust must remain balanced, and an exhaust-loss interlock warns or stops cabinet operation if the external system fails. The configuration can support biological work involving limited evaluated volatile chemicals when the complete installation and procedure are suitable.

Ana Özellikler

All work-zone air leaves through the hard-ducted exhaust connection.

A dedicated supply HEPA stage provides clean vertical air over the product.

Exhaust-loss monitoring protects the inward containment boundary.

Negative-pressure plenums enclose contaminated internal air paths.

A serviceable exhaust transition coordinates the cabinet with building ductwork.

Müşteri Ürün Sorunları

A B2 cabinet depends on the building exhaust system, so cabinet airflow, room balance and duct performance must operate together.

Exhaust failure reverses or weakens face containment.An exhaust interlock alarms and can disable the cabinet supply when duct flow is lost.
Building airflow changes disturb cabinet balance.A coordinated exhaust valve and pressure sensing stabilize the cabinet connection.
Heat and conditioned air are continuously exhausted.Efficient EC blowers and correctly sized duct control reduce avoidable energy demand.
Users assume any chemical quantity is acceptable.The application is limited to substances and quantities evaluated for the complete exhaust installation.

Tipik uygulamalar

Biological work with evaluated volatile chemical useToxicological studiesPharmaceutical microbiology requiring total exhaustSpecialized clinical laboratory procedures

Teknik parametreler

Typical configurable construction ranges for a Class II Type B2 biological safety cabinet are listed below.

Temel malzemelerSUS316L work-zone liner with powder-coated steel outer shell and mineral-wool insulated supply and exhaust plenums
Panel kalınlığı40-75 mm double-skin supply and exhaust sections
Effective Width (Etkili Genişlik)1200-1800 mm clear working width
Maksimum uzunlukUp to 2600 mm overall cabinet height including exhaust transition
Çelik yüz yüze kalınlığı1.2-1.5 mm SUS316L inner liner; 1.0-1.2 mm outer steel
Core Density (Çekirdek Yoğunluğu)100-140 kg/m³ mineral-wool plenum insulation
Termal İletkenlik0.035-0.045 W/(m·K) for the mineral-wool insulation
Yüzey bitirmeFine-brushed SUS316L work zone with sealed white powder-coated exterior
Ortak tipWelded negative-pressure inner plenums with gasketed HEPA frames and flanged hard-duct exhaust transition
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Mevcut Seçenekler

1200 or 1800 mm work widthMotorized sashBuilding exhaust control valveSUS304 or SUS316L work zone

Planning a Class II Type B2 Biological Safety Cabinet specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat

Ana Sayfa

Ürünler

Haberler

Hakkımızda

İletişim