Monitor de placa de carga
- Elevated isolated plate measures positive and negative ionizer decay performance.
- Digital sequence reports decay time and residual offset voltage on one clear display.
- Separate charging probe supports repeatable plate charging without disturbing the instrument setup.
Introdução do produto
This monitor uses a square brushed-stainless plate supported above the instrument base by four insulating standoffs. The isolated plate receives a known electrostatic charge, then measures how quickly an ionizer reduces that charge to a defined endpoint. The amber front display presents polarity, voltage, decay time and balance information, while four direct keys control the test sequence. A separate cabled charging probe applies the initial plate potential without requiring the operator to handle the sensing surface.
Características-chave
Positive and negative decay cycles reveal neutralization performance for both polarities.
Balance or offset measurement identifies excess positive or negative ion output.
Four low-leakage standoffs maintain the plate air gap and electrical isolation.
Amber digital display remains readable under typical bench and clean manufacturing lighting.
Cabled charging probe keeps the charging source separate from the measurement controls.
Compact metal base supports stable positioning in front of blowers, bars and ionizing guns.
Preocupações do produto do cliente
Ionizer performance cannot be judged from airflow alone; a controlled conductive target and repeatable voltage thresholds are needed to compare decay time and positive/negative balance.
Aplicações típicas
Parâmetros técnicos
The representative bench configuration below supports controlled ionizer decay and balance checks. Plate area, start/stop thresholds, polarity sequence, timer range, data output and probe charging level can be configured around the selected verification method.
| Material principal | Brushed-stainless sensing plate with low-leakage PTFE supports and powder-coated steel base |
|---|---|
| Painel de espessura | 2.0–3.0 mm instrument enclosure-panel thickness |
| Largura efetiva | 150–180 mm active plate width |
| Comprimento máximo | Up to 280 mm instrument depth |
| Aço enfrentando espessura | 1.0–1.5 mm stainless sensing-plate thickness |
| Densidade Core | 7800–8000 kg/m³ stainless-steel plate density |
| Condutividade térmica | 14–17 W/(m·K) for the stainless sensing plate |
| Superfície acabado | Brushed stainless plate, white PTFE standoffs and matte charcoal powder-coated base |
| Tipo conjunto | Isolated four-standoff charge plate connected to digital timer/balance electronics and detachable charging probe |
| Customização | Disponível com base na aplicação pretendida e no ambiente operacional. |
Opções disponíveis
Planning a Charge Plate Monitor specification?
Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Inglês
Alemão
Língua árabe
Francês
Língua indonésia
Japonês
Coreano
Língua malaia
Portuguêsatual
Língua russa
Espanhol
Tailandês
Língua turca
Vietnã