شحن لوحة مراقب
- Elevated isolated plate measures positive and negative ionizer decay performance.
- Digital sequence reports decay time and residual offset voltage on one clear display.
- Separate charging probe supports repeatable plate charging without disturbing the instrument setup.
مقدمة المنتج
This monitor uses a square brushed-stainless plate supported above the instrument base by four insulating standoffs. The isolated plate receives a known electrostatic charge, then measures how quickly an ionizer reduces that charge to a defined endpoint. The amber front display presents polarity, voltage, decay time and balance information, while four direct keys control the test sequence. A separate cabled charging probe applies the initial plate potential without requiring the operator to handle the sensing surface.
الخصائص الرئيسية
Positive and negative decay cycles reveal neutralization performance for both polarities.
Balance or offset measurement identifies excess positive or negative ion output.
Four low-leakage standoffs maintain the plate air gap and electrical isolation.
Amber digital display remains readable under typical bench and clean manufacturing lighting.
Cabled charging probe keeps the charging source separate from the measurement controls.
Compact metal base supports stable positioning in front of blowers, bars and ionizing guns.
مخاوف المنتج للعملاء
Ionizer performance cannot be judged from airflow alone; a controlled conductive target and repeatable voltage thresholds are needed to compare decay time and positive/negative balance.
تطبيقات نموذجية
المعلمات الفنية
The representative bench configuration below supports controlled ionizer decay and balance checks. Plate area, start/stop thresholds, polarity sequence, timer range, data output and probe charging level can be configured around the selected verification method.
| المواد الأساسية | Brushed-stainless sensing plate with low-leakage PTFE supports and powder-coated steel base |
|---|---|
| سمك اللوحة | 2.0–3.0 mm instrument enclosure-panel thickness |
| العرض الفعال | 150–180 mm active plate width |
| الحد الأقصى الطول | Up to 280 mm instrument depth |
| الصلب يواجه سمك | 1.0–1.5 mm stainless sensing-plate thickness |
| الكثافة الأساسية | 7800–8000 kg/m³ stainless-steel plate density |
| الموصلية الحرارية | 14–17 W/(m·K) for the stainless sensing plate |
| إنهاء السطح | Brushed stainless plate, white PTFE standoffs and matte charcoal powder-coated base |
| نوع المشترك | Isolated four-standoff charge plate connected to digital timer/balance electronics and detachable charging probe |
| التخصيص | متوفر على أساس التطبيق المقصود وبيئة التشغيل. |
الخيارات المتاحة
Planning a Charge Plate Monitor specification?
أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

English
الألمانية
العربيةالحالي
الفرنسية
الإندونيسية
اليابانية
الكورية
اللغة الملاوية
البرتغالية
الروسية
الإسبانية
التايلاندية
اللغة التركية
اللغة الفيتنامية