Monitor Plat Caj
- Elevated isolated plate measures positive and negative ionizer decay performance.
- Digital sequence reports decay time and residual offset voltage on one clear display.
- Separate charging probe supports repeatable plate charging without disturbing the instrument setup.
Pengenalan Produk
This monitor uses a square brushed-stainless plate supported above the instrument base by four insulating standoffs. The isolated plate receives a known electrostatic charge, then measures how quickly an ionizer reduces that charge to a defined endpoint. The amber front display presents polarity, voltage, decay time and balance information, while four direct keys control the test sequence. A separate cabled charging probe applies the initial plate potential without requiring the operator to handle the sensing surface.
Ciri-ciri Utama
Positive and negative decay cycles reveal neutralization performance for both polarities.
Balance or offset measurement identifies excess positive or negative ion output.
Four low-leakage standoffs maintain the plate air gap and electrical isolation.
Amber digital display remains readable under typical bench and clean manufacturing lighting.
Cabled charging probe keeps the charging source separate from the measurement controls.
Compact metal base supports stable positioning in front of blowers, bars and ionizing guns.
Kebimbangan Produk Pelanggan
Ionizer performance cannot be judged from airflow alone; a controlled conductive target and repeatable voltage thresholds are needed to compare decay time and positive/negative balance.
Permohonan yang biasa
Parameter teknikal
The representative bench configuration below supports controlled ionizer decay and balance checks. Plate area, start/stop thresholds, polarity sequence, timer range, data output and probe charging level can be configured around the selected verification method.
| Bahan Teras | Brushed-stainless sensing plate with low-leakage PTFE supports and powder-coated steel base |
|---|---|
| Ketebalan Panel | 2.0–3.0 mm instrument enclosure-panel thickness |
| Lebar berkesan | 150–180 mm active plate width |
| Panjang maksimum | Up to 280 mm instrument depth |
| Keluli Menghadapi Ketebalan | 1.0–1.5 mm stainless sensing-plate thickness |
| Ketumpatan teras | 7800–8000 kg/m³ stainless-steel plate density |
| Kekonduksian Terma | 14–17 W/(m·K) for the stainless sensing plate |
| Kemasan permukaan | Brushed stainless plate, white PTFE standoffs and matte charcoal powder-coated base |
| Jenis Bersatu | Isolated four-standoff charge plate connected to digital timer/balance electronics and detachable charging probe |
| Penyesuaian | Boleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi. |
Pilihan yang boleh didapati
Planning a Charge Plate Monitor specification?
Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Bahasa Inggeris
Bahasa Jerman
Bahasa Arab (Bahasa Melayu)
Bahasa Perancis
Bahasa Indonesia: Bahasa Indonesia
Bahasa Jepun
Bahasa Korea (Bahasa Melayu)
Bahasa Melayu (Bahasa Melayu)Semasa
Bahasa Portugis: Bahasa Portugis: Bahasa Portugis
Bahasa Rusia
Bahasa Sepanyol: Bahasa Sepanyol: Bahasa Sepanyol
Bahasa Melayu (Bahasa Melayu)
Bahasa Turki: Bahasa Turki
Bahasa Vietnam (Bahasa Melayu)