Pengisian Pelat Monitor
- Elevated isolated plate measures positive and negative ionizer decay performance.
- Digital sequence reports decay time and residual offset voltage on one clear display.
- Separate charging probe supports repeatable plate charging without disturbing the instrument setup.
Perkenalan produk
This monitor uses a square brushed-stainless plate supported above the instrument base by four insulating standoffs. The isolated plate receives a known electrostatic charge, then measures how quickly an ionizer reduces that charge to a defined endpoint. The amber front display presents polarity, voltage, decay time and balance information, while four direct keys control the test sequence. A separate cabled charging probe applies the initial plate potential without requiring the operator to handle the sensing surface.
Fitur utama:
Positive and negative decay cycles reveal neutralization performance for both polarities.
Balance or offset measurement identifies excess positive or negative ion output.
Four low-leakage standoffs maintain the plate air gap and electrical isolation.
Amber digital display remains readable under typical bench and clean manufacturing lighting.
Cabled charging probe keeps the charging source separate from the measurement controls.
Compact metal base supports stable positioning in front of blowers, bars and ionizing guns.
Kekhawatiran produk pelanggan
Ionizer performance cannot be judged from airflow alone; a controlled conductive target and repeatable voltage thresholds are needed to compare decay time and positive/negative balance.
Aplikasi yang Tipis
Parameter teknis
The representative bench configuration below supports controlled ionizer decay and balance checks. Plate area, start/stop thresholds, polarity sequence, timer range, data output and probe charging level can be configured around the selected verification method.
| Bahan inti | Brushed-stainless sensing plate with low-leakage PTFE supports and powder-coated steel base |
|---|---|
| Ketebalan Panel (Panel Thickness) | 2.0–3.0 mm instrument enclosure-panel thickness |
| Efektif lebar | 150–180 mm active plate width |
| Panjang maksimum | Up to 280 mm instrument depth |
| Baja menghadap ketebalan | 1.0–1.5 mm stainless sensing-plate thickness |
| Kepadatan inti (core density) | 7800–8000 kg/m³ stainless-steel plate density |
| Konduktivitas Termal (Thermal Conductivity) | 14–17 W/(m·K) for the stainless sensing plate |
| Permukaan selesai | Brushed stainless plate, white PTFE standoffs and matte charcoal powder-coated base |
| Jenis Bersama | Isolated four-standoff charge plate connected to digital timer/balance electronics and detachable charging probe |
| Customization (Kustomisasi) | Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi. |
Pilihan yang tersedia
Planning a Charge Plate Monitor specification?
Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.