Монитор зарядной плиты
- Elevated isolated plate measures positive and negative ionizer decay performance.
- Digital sequence reports decay time and residual offset voltage on one clear display.
- Separate charging probe supports repeatable plate charging without disturbing the instrument setup.
Введение продукции
This monitor uses a square brushed-stainless plate supported above the instrument base by four insulating standoffs. The isolated plate receives a known electrostatic charge, then measures how quickly an ionizer reduces that charge to a defined endpoint. The amber front display presents polarity, voltage, decay time and balance information, while four direct keys control the test sequence. A separate cabled charging probe applies the initial plate potential without requiring the operator to handle the sensing surface.
Основные характеристики
Positive and negative decay cycles reveal neutralization performance for both polarities.
Balance or offset measurement identifies excess positive or negative ion output.
Four low-leakage standoffs maintain the plate air gap and electrical isolation.
Amber digital display remains readable under typical bench and clean manufacturing lighting.
Cabled charging probe keeps the charging source separate from the measurement controls.
Compact metal base supports stable positioning in front of blowers, bars and ionizing guns.
Обеспокоенность клиентов продуктами
Ionizer performance cannot be judged from airflow alone; a controlled conductive target and repeatable voltage thresholds are needed to compare decay time and positive/negative balance.
Типичные приложения
Технические параметры
The representative bench configuration below supports controlled ionizer decay and balance checks. Plate area, start/stop thresholds, polarity sequence, timer range, data output and probe charging level can be configured around the selected verification method.
| Основной материал | Brushed-stainless sensing plate with low-leakage PTFE supports and powder-coated steel base |
|---|---|
| Толщина панели | 2.0–3.0 mm instrument enclosure-panel thickness |
| эффективная ширина | 150–180 mm active plate width |
| Максимальная длина | Up to 280 mm instrument depth |
| Толщина линий стали | 1.0–1.5 mm stainless sensing-plate thickness |
| Плотность ядра | 7800–8000 kg/m³ stainless-steel plate density |
| Теплопроводимость | 14–17 W/(m·K) for the stainless sensing plate |
| Поверхностная отделка | Brushed stainless plate, white PTFE standoffs and matte charcoal powder-coated base |
| Объединенный тип | Isolated four-standoff charge plate connected to digital timer/balance electronics and detachable charging probe |
| Customization | Доступно в зависимости от предполагаемого применения и операционной среды. |
Доступные варианты
Planning a Charge Plate Monitor specification?
Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.

English
Немецкий
Арабский язык
Французский
Индонезийский
Японский язык
Корейский
Японский
Португальский
Русский языкТекущий
Испанский язык
Тайский
Турецкий
Вьетнамский язык