- Elevated isolated plate measures positive and negative ionizer decay performance.
- Digital sequence reports decay time and residual offset voltage on one clear display.
- Separate charging probe supports repeatable plate charging without disturbing the instrument setup.
Giới thiệu Sản phẩm
This monitor uses a square brushed-stainless plate supported above the instrument base by four insulating standoffs. The isolated plate receives a known electrostatic charge, then measures how quickly an ionizer reduces that charge to a defined endpoint. The amber front display presents polarity, voltage, decay time and balance information, while four direct keys control the test sequence. A separate cabled charging probe applies the initial plate potential without requiring the operator to handle the sensing surface.
Các tính năng chính
Positive and negative decay cycles reveal neutralization performance for both polarities.
Balance or offset measurement identifies excess positive or negative ion output.
Four low-leakage standoffs maintain the plate air gap and electrical isolation.
Amber digital display remains readable under typical bench and clean manufacturing lighting.
Cabled charging probe keeps the charging source separate from the measurement controls.
Compact metal base supports stable positioning in front of blowers, bars and ionizing guns.
Các mối quan tâm về sản phẩm của khách hàng
Ionizer performance cannot be judged from airflow alone; a controlled conductive target and repeatable voltage thresholds are needed to compare decay time and positive/negative balance.
Các ứng dụng điển hình
Thông số kỹ thuật
The representative bench configuration below supports controlled ionizer decay and balance checks. Plate area, start/stop thresholds, polarity sequence, timer range, data output and probe charging level can be configured around the selected verification method.
| Vật liệu lõi | Brushed-stainless sensing plate with low-leakage PTFE supports and powder-coated steel base |
|---|---|
| Độ dày bảng điều khiển | 2.0–3.0 mm instrument enclosure-panel thickness |
| Chiều rộng hiệu quả | 150–180 mm active plate width |
| Chiều dài tối đa | Up to 280 mm instrument depth |
| Thép đối mặt với độ dày | 1.0–1.5 mm stainless sensing-plate thickness |
| Mật độ lõi | 7800–8000 kg/m³ stainless-steel plate density |
| Độ dẫn nhiệt | 14–17 W/(m·K) for the stainless sensing plate |
| Kết thúc bề mặt | Brushed stainless plate, white PTFE standoffs and matte charcoal powder-coated base |
| Loại khớp nối | Isolated four-standoff charge plate connected to digital timer/balance electronics and detachable charging probe |
| Tùy chỉnh | Có sẵn dựa trên ứng dụng dự định và môi trường hoạt động. |
Các tùy chọn có sẵn
Planning a Charge Plate Monitor specification?
Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Tiếng Anh
Tiếng Đức, tiếng Đức
Tiếng Ả Rập, tiếng Ả Rập
Tiếng Pháp, tiếng Pháp
Tiếng Indonesia (tiếng Việt)
Tiếng Nhật
Tiếng Hàn / tiếng Hàn
Tiếng Mã Lai
Tiếng Bồ Đào Nha, tiếng Bồ Đào Nha
Tiếng Nga, tiếng Nga
Tiếng Tây Ban Nha, tiếng Tây Ban Nha
Tiếng Thái (tiếng Thái)
Tiếng Thổ Nhĩ Kỳ, tiếng Thổ Nhĩ Kỳ
Tiếng Việt / tiếng ViệtHiện tại