充電プレートモニター
- Elevated isolated plate measures positive and negative ionizer decay performance.
- Digital sequence reports decay time and residual offset voltage on one clear display.
- Separate charging probe supports repeatable plate charging without disturbing the instrument setup.
商品紹介
This monitor uses a square brushed-stainless plate supported above the instrument base by four insulating standoffs. The isolated plate receives a known electrostatic charge, then measures how quickly an ionizer reduces that charge to a defined endpoint. The amber front display presents polarity, voltage, decay time and balance information, while four direct keys control the test sequence. A separate cabled charging probe applies the initial plate potential without requiring the operator to handle the sensing surface.
主要な特徴
Positive and negative decay cycles reveal neutralization performance for both polarities.
Balance or offset measurement identifies excess positive or negative ion output.
Four low-leakage standoffs maintain the plate air gap and electrical isolation.
Amber digital display remains readable under typical bench and clean manufacturing lighting.
Cabled charging probe keeps the charging source separate from the measurement controls.
Compact metal base supports stable positioning in front of blowers, bars and ionizing guns.
お客様の製品に関する懸念事項
Ionizer performance cannot be judged from airflow alone; a controlled conductive target and repeatable voltage thresholds are needed to compare decay time and positive/negative balance.
典型的な用途
技術的なパラメータ
The representative bench configuration below supports controlled ionizer decay and balance checks. Plate area, start/stop thresholds, polarity sequence, timer range, data output and probe charging level can be configured around the selected verification method.
| コア材料 | Brushed-stainless sensing plate with low-leakage PTFE supports and powder-coated steel base |
|---|---|
| パネルの厚さ | 2.0–3.0 mm instrument enclosure-panel thickness |
| 有効幅 | 150–180 mm active plate width |
| 最大長さ | Up to 280 mm instrument depth |
| 鋼鉄の厚さを直面する | 1.0–1.5 mm stainless sensing-plate thickness |
| コア密度 | 7800–8000 kg/m³ stainless-steel plate density |
| 熱伝導率 | 14–17 W/(m·K) for the stainless sensing plate |
| 表面仕上げ | Brushed stainless plate, white PTFE standoffs and matte charcoal powder-coated base |
| ジョイントタイプ | Isolated four-standoff charge plate connected to digital timer/balance electronics and detachable charging probe |
| カスタマイズ | 意図したアプリケーションと動作環境に基づいて利用できます。 |