Charge Plate Monitor
- Elevated isolated plate measures positive and negative ionizer decay performance.
- Digital sequence reports decay time and residual offset voltage on one clear display.
- Separate charging probe supports repeatable plate charging without disturbing the instrument setup.
Produkteinführung
This monitor uses a square brushed-stainless plate supported above the instrument base by four insulating standoffs. The isolated plate receives a known electrostatic charge, then measures how quickly an ionizer reduces that charge to a defined endpoint. The amber front display presents polarity, voltage, decay time and balance information, while four direct keys control the test sequence. A separate cabled charging probe applies the initial plate potential without requiring the operator to handle the sensing surface.
Key Features
Positive and negative decay cycles reveal neutralization performance for both polarities.
Balance or offset measurement identifies excess positive or negative ion output.
Four low-leakage standoffs maintain the plate air gap and electrical isolation.
Amber digital display remains readable under typical bench and clean manufacturing lighting.
Cabled charging probe keeps the charging source separate from the measurement controls.
Compact metal base supports stable positioning in front of blowers, bars and ionizing guns.
Kunden Produktbedenken
Ionizer performance cannot be judged from airflow alone; a controlled conductive target and repeatable voltage thresholds are needed to compare decay time and positive/negative balance.
Typische Anwendungen
Technische Parameter
The representative bench configuration below supports controlled ionizer decay and balance checks. Plate area, start/stop thresholds, polarity sequence, timer range, data output and probe charging level can be configured around the selected verification method.
| Core Material | Brushed-stainless sensing plate with low-leakage PTFE supports and powder-coated steel base |
|---|---|
| Panel Dicke | 2.0–3.0 mm instrument enclosure-panel thickness |
| Effektive Breite | 150–180 mm active plate width |
| Maximale Länge | Up to 280 mm instrument depth |
| Stahl facing Dicke | 1.0–1.5 mm stainless sensing-plate thickness |
| Kerndichte | 7800–8000 kg/m³ stainless-steel plate density |
| Thermische Leitfähigkeit | 14–17 W/(m·K) for the stainless sensing plate |
| Oberfläche Finish | Brushed stainless plate, white PTFE standoffs and matte charcoal powder-coated base |
| Gemeinsamer Typ | Isolated four-standoff charge plate connected to digital timer/balance electronics and detachable charging probe |
| Customisierung | Verfügbar je nach beabsichtigter Anwendung und Betriebsumgebung. |
Verfügbare Optionen
Planning a Charge Plate Monitor specification?
Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Englisch
DeutschCurrent
Arabisch
Französisch
indonesisch
Japanisch
Koreanisch
Malaiisch
Portugiesisch
Russisch
Spanisch
Thailändisch
Türkischer Sprache
Vietnamesisch