Liquid Particle Counter
- Metered liquid volumes support repeatable sample counts.
- Light obscuration resolves multiple particle thresholds.
- Small samples and automated rinsing limit material use.
Product Introduction
This liquid particle counter draws a controlled sample volume through a laser light-obscuration sensor, where individual particles are sized from the reduction in transmitted light. A precision syringe or piston sampling system supports repeatable volume delivery, while programmable test routines manage flush, measurement and reporting steps. Interchangeable sensor ranges allow the platform to address parenteral products, purified water, solvents, oils and other compatible liquids.
Key Features
Light-obscuration sensing provides simultaneous particle counts across multiple size thresholds.
Small-volume probe options reduce product consumption for high-value formulations.
Automated flush routines limit carryover between samples and reduce manual handling.
Bubble and sensor-condition alerts help distinguish sampling faults from genuine particle events.
Configurable methods store sample volume, replicates, thresholds and reporting calculations together.
Customer Product Concerns
Reliable liquid counts require bubble control, thorough carryover removal between samples, and repeatable results from the smallest practical volume of costly product.
Typical Applications
Technical Parameters
The table summarizes representative analyzer, probe, flow-path, and sample-interface materials and dimensions for a liquid counter, with selection based on viscosity, sample volume, and particle-size thresholds.
| Core Material | Powder-coated or stainless instrument enclosure with a glass-and-stainless sampling path, precision syringe assembly and laser sensor |
|---|---|
| Panel Thickness | Typically 1.0–1.5 mm enclosure panel thickness |
| Effective Width | Approximately 300–360 mm according to sampler configuration |
| Maximum Length | Approximately 330–500 mm including sample probe and syringe mechanism |
| Steel Facing Thickness | Approximately 1.0–1.5 mm where stainless enclosure panels are specified |
| Core Density | Not applicable; no insulation core is used (0 kg/m³) |
| Thermal Conductivity | Approximately 14–16 W/(m·K) for stainless wetted and enclosure components |
| Surface Finish | Smooth light-gray wipe-clean coating with passivated stainless and glass sample-contact surfaces |
| Joint Type | Luer or compression sample probe connection with removable sensor tubing and waste outlet |
| Customization | Available based on the intended application and operating environment. |
Available Options
Planning a Liquid Particle Counter specification?
Send us your dimensions, installation conditions, performance targets and required surface finish.

EnglishCurrent
德语
阿拉伯语
法语
印尼语
日语
韩语
马来语
葡萄牙语
俄语
西班牙语
泰语
土耳其语
越南语