عداد الجسيمات السائلة
- Metered liquid volumes support repeatable sample counts.
- Light obscuration resolves multiple particle thresholds.
- Small samples and automated rinsing limit material use.
مقدمة المنتج
This liquid particle counter draws a controlled sample volume through a laser light-obscuration sensor, where individual particles are sized from the reduction in transmitted light. A precision syringe or piston sampling system supports repeatable volume delivery, while programmable test routines manage flush, measurement and reporting steps. Interchangeable sensor ranges allow the platform to address parenteral products, purified water, solvents, oils and other compatible liquids.
الخصائص الرئيسية
Light-obscuration sensing provides simultaneous particle counts across multiple size thresholds.
Small-volume probe options reduce product consumption for high-value formulations.
Automated flush routines limit carryover between samples and reduce manual handling.
Bubble and sensor-condition alerts help distinguish sampling faults from genuine particle events.
Configurable methods store sample volume, replicates, thresholds and reporting calculations together.
مخاوف المنتج للعملاء
Reliable liquid counts require bubble control, thorough carryover removal between samples, and repeatable results from the smallest practical volume of costly product.
تطبيقات نموذجية
المعلمات الفنية
The table summarizes representative analyzer, probe, flow-path, and sample-interface materials and dimensions for a liquid counter, with selection based on viscosity, sample volume, and particle-size thresholds.
| المواد الأساسية | Powder-coated or stainless instrument enclosure with a glass-and-stainless sampling path, precision syringe assembly and laser sensor |
|---|---|
| سمك اللوحة | Typically 1.0–1.5 mm enclosure panel thickness |
| العرض الفعال | Approximately 300–360 mm according to sampler configuration |
| الحد الأقصى الطول | Approximately 330–500 mm including sample probe and syringe mechanism |
| الصلب يواجه سمك | Approximately 1.0–1.5 mm where stainless enclosure panels are specified |
| الكثافة الأساسية | Not applicable; no insulation core is used (0 kg/m³) |
| الموصلية الحرارية | Approximately 14–16 W/(m·K) for stainless wetted and enclosure components |
| إنهاء السطح | Smooth light-gray wipe-clean coating with passivated stainless and glass sample-contact surfaces |
| نوع المشترك | Luer or compression sample probe connection with removable sensor tubing and waste outlet |
| التخصيص | متوفر على أساس التطبيق المقصود وبيئة التشغيل. |
الخيارات المتاحة
Planning a Liquid Particle Counter specification?
أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

English
الألمانية
العربيةالحالي
الفرنسية
الإندونيسية
اليابانية
الكورية
اللغة الملاوية
البرتغالية
الروسية
الإسبانية
التايلاندية
اللغة التركية
اللغة الفيتنامية