Liquid Particle Counter
- Metered liquid volumes support repeatable sample counts.
- Light obscuration resolves multiple particle thresholds.
- Small samples and automated rinsing limit material use.
Produkteinführung
This liquid particle counter draws a controlled sample volume through a laser light-obscuration sensor, where individual particles are sized from the reduction in transmitted light. A precision syringe or piston sampling system supports repeatable volume delivery, while programmable test routines manage flush, measurement and reporting steps. Interchangeable sensor ranges allow the platform to address parenteral products, purified water, solvents, oils and other compatible liquids.
Key Features
Light-obscuration sensing provides simultaneous particle counts across multiple size thresholds.
Small-volume probe options reduce product consumption for high-value formulations.
Automated flush routines limit carryover between samples and reduce manual handling.
Bubble and sensor-condition alerts help distinguish sampling faults from genuine particle events.
Configurable methods store sample volume, replicates, thresholds and reporting calculations together.
Kunden Produktbedenken
Reliable liquid counts require bubble control, thorough carryover removal between samples, and repeatable results from the smallest practical volume of costly product.
Typische Anwendungen
Technische Parameter
The table summarizes representative analyzer, probe, flow-path, and sample-interface materials and dimensions for a liquid counter, with selection based on viscosity, sample volume, and particle-size thresholds.
| Core Material | Powder-coated or stainless instrument enclosure with a glass-and-stainless sampling path, precision syringe assembly and laser sensor |
|---|---|
| Panel Dicke | Typically 1.0–1.5 mm enclosure panel thickness |
| Effektive Breite | Approximately 300–360 mm according to sampler configuration |
| Maximale Länge | Approximately 330–500 mm including sample probe and syringe mechanism |
| Stahl facing Dicke | Approximately 1.0–1.5 mm where stainless enclosure panels are specified |
| Kerndichte | Not applicable; no insulation core is used (0 kg/m³) |
| Thermische Leitfähigkeit | Approximately 14–16 W/(m·K) for stainless wetted and enclosure components |
| Oberfläche Finish | Smooth light-gray wipe-clean coating with passivated stainless and glass sample-contact surfaces |
| Gemeinsamer Typ | Luer or compression sample probe connection with removable sensor tubing and waste outlet |
| Customisierung | Verfügbar je nach beabsichtigter Anwendung und Betriebsumgebung. |
Verfügbare Optionen
Planning a Liquid Particle Counter specification?