Sıvı Parçacık Sayıcı
- Metered liquid volumes support repeatable sample counts.
- Light obscuration resolves multiple particle thresholds.
- Small samples and automated rinsing limit material use.
Ürün tanıtımı
This liquid particle counter draws a controlled sample volume through a laser light-obscuration sensor, where individual particles are sized from the reduction in transmitted light. A precision syringe or piston sampling system supports repeatable volume delivery, while programmable test routines manage flush, measurement and reporting steps. Interchangeable sensor ranges allow the platform to address parenteral products, purified water, solvents, oils and other compatible liquids.
Ana Özellikler
Light-obscuration sensing provides simultaneous particle counts across multiple size thresholds.
Small-volume probe options reduce product consumption for high-value formulations.
Automated flush routines limit carryover between samples and reduce manual handling.
Bubble and sensor-condition alerts help distinguish sampling faults from genuine particle events.
Configurable methods store sample volume, replicates, thresholds and reporting calculations together.
Müşteri Ürün Sorunları
Reliable liquid counts require bubble control, thorough carryover removal between samples, and repeatable results from the smallest practical volume of costly product.
Tipik uygulamalar
Teknik parametreler
The table summarizes representative analyzer, probe, flow-path, and sample-interface materials and dimensions for a liquid counter, with selection based on viscosity, sample volume, and particle-size thresholds.
| Temel malzemeler | Powder-coated or stainless instrument enclosure with a glass-and-stainless sampling path, precision syringe assembly and laser sensor |
|---|---|
| Panel kalınlığı | Typically 1.0–1.5 mm enclosure panel thickness |
| Effective Width (Etkili Genişlik) | Approximately 300–360 mm according to sampler configuration |
| Maksimum uzunluk | Approximately 330–500 mm including sample probe and syringe mechanism |
| Çelik yüz yüze kalınlığı | Approximately 1.0–1.5 mm where stainless enclosure panels are specified |
| Core Density (Çekirdek Yoğunluğu) | Not applicable; no insulation core is used (0 kg/m³) |
| Termal İletkenlik | Approximately 14–16 W/(m·K) for stainless wetted and enclosure components |
| Yüzey bitirme | Smooth light-gray wipe-clean coating with passivated stainless and glass sample-contact surfaces |
| Ortak tip | Luer or compression sample probe connection with removable sensor tubing and waste outlet |
| Customization (Özelleşme) | Kullanılan uygulama ve çalışma ortamına göre kullanılabilir. |
Mevcut Seçenekler
Planning a Liquid Particle Counter specification?
Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

İngilizce
Almanca
Arapça
Fransızca
Endonezya dilinde
Japonca
Korece
Malay dilinde
Portekizce
Rusça
İspanyolca
Taylandca
TürkçeCurrent
Vietnamca