Bộ đếm hạt lỏng
- Metered liquid volumes support repeatable sample counts.
- Light obscuration resolves multiple particle thresholds.
- Small samples and automated rinsing limit material use.
Giới thiệu Sản phẩm
This liquid particle counter draws a controlled sample volume through a laser light-obscuration sensor, where individual particles are sized from the reduction in transmitted light. A precision syringe or piston sampling system supports repeatable volume delivery, while programmable test routines manage flush, measurement and reporting steps. Interchangeable sensor ranges allow the platform to address parenteral products, purified water, solvents, oils and other compatible liquids.
Các tính năng chính
Light-obscuration sensing provides simultaneous particle counts across multiple size thresholds.
Small-volume probe options reduce product consumption for high-value formulations.
Automated flush routines limit carryover between samples and reduce manual handling.
Bubble and sensor-condition alerts help distinguish sampling faults from genuine particle events.
Configurable methods store sample volume, replicates, thresholds and reporting calculations together.
Các mối quan tâm về sản phẩm của khách hàng
Reliable liquid counts require bubble control, thorough carryover removal between samples, and repeatable results from the smallest practical volume of costly product.
Các ứng dụng điển hình
Thông số kỹ thuật
The table summarizes representative analyzer, probe, flow-path, and sample-interface materials and dimensions for a liquid counter, with selection based on viscosity, sample volume, and particle-size thresholds.
| Vật liệu lõi | Powder-coated or stainless instrument enclosure with a glass-and-stainless sampling path, precision syringe assembly and laser sensor |
|---|---|
| Độ dày bảng điều khiển | Typically 1.0–1.5 mm enclosure panel thickness |
| Chiều rộng hiệu quả | Approximately 300–360 mm according to sampler configuration |
| Chiều dài tối đa | Approximately 330–500 mm including sample probe and syringe mechanism |
| Thép đối mặt với độ dày | Approximately 1.0–1.5 mm where stainless enclosure panels are specified |
| Mật độ lõi | Not applicable; no insulation core is used (0 kg/m³) |
| Độ dẫn nhiệt | Approximately 14–16 W/(m·K) for stainless wetted and enclosure components |
| Kết thúc bề mặt | Smooth light-gray wipe-clean coating with passivated stainless and glass sample-contact surfaces |
| Loại khớp nối | Luer or compression sample probe connection with removable sensor tubing and waste outlet |
| Tùy chỉnh | Có sẵn dựa trên ứng dụng dự định và môi trường hoạt động. |
Các tùy chọn có sẵn
Planning a Liquid Particle Counter specification?
Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Tiếng Anh
Tiếng Đức, tiếng Đức
Tiếng Ả Rập, tiếng Ả Rập
Tiếng Pháp, tiếng Pháp
Tiếng Indonesia (tiếng Việt)
Tiếng Nhật
Tiếng Hàn / tiếng Hàn
Tiếng Mã Lai
Tiếng Bồ Đào Nha, tiếng Bồ Đào Nha
Tiếng Nga, tiếng Nga
Tiếng Tây Ban Nha, tiếng Tây Ban Nha
Tiếng Thái (tiếng Thái)
Tiếng Thổ Nhĩ Kỳ, tiếng Thổ Nhĩ Kỳ
Tiếng Việt / tiếng ViệtHiện tại