Contador de partículas líquidas
- Metered liquid volumes support repeatable sample counts.
- Light obscuration resolves multiple particle thresholds.
- Small samples and automated rinsing limit material use.
Introducción del producto
This liquid particle counter draws a controlled sample volume through a laser light-obscuration sensor, where individual particles are sized from the reduction in transmitted light. A precision syringe or piston sampling system supports repeatable volume delivery, while programmable test routines manage flush, measurement and reporting steps. Interchangeable sensor ranges allow the platform to address parenteral products, purified water, solvents, oils and other compatible liquids.
Características clave
Light-obscuration sensing provides simultaneous particle counts across multiple size thresholds.
Small-volume probe options reduce product consumption for high-value formulations.
Automated flush routines limit carryover between samples and reduce manual handling.
Bubble and sensor-condition alerts help distinguish sampling faults from genuine particle events.
Configurable methods store sample volume, replicates, thresholds and reporting calculations together.
Preocupaciones del producto del cliente
Reliable liquid counts require bubble control, thorough carryover removal between samples, and repeatable results from the smallest practical volume of costly product.
Aplicaciones típicas
Parámetros técnicos
The table summarizes representative analyzer, probe, flow-path, and sample-interface materials and dimensions for a liquid counter, with selection based on viscosity, sample volume, and particle-size thresholds.
| Materiales Core | Powder-coated or stainless instrument enclosure with a glass-and-stainless sampling path, precision syringe assembly and laser sensor |
|---|---|
| Panel de espesor | Typically 1.0–1.5 mm enclosure panel thickness |
| Ancho efectivo | Approximately 300–360 mm according to sampler configuration |
| Longitud máxima | Approximately 330–500 mm including sample probe and syringe mechanism |
| Acero frente a espesor | Approximately 1.0–1.5 mm where stainless enclosure panels are specified |
| Densidad Core | Not applicable; no insulation core is used (0 kg/m³) |
| Conductividad térmica | Approximately 14–16 W/(m·K) for stainless wetted and enclosure components |
| Superficie acabada | Smooth light-gray wipe-clean coating with passivated stainless and glass sample-contact surfaces |
| Tipo conjunto | Luer or compression sample probe connection with removable sensor tubing and waste outlet |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
Planning a Liquid Particle Counter specification?
Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Inglés
Alemán
El árabe
Francés
Idioma indonesio
El japonés
Coreano
El malayo
El portugués
El ruso
EspañolCurrent
Tailandés
El turco
El vietnamita