غرفة نظيفة ضوء الطوارئ
A sealed emergency luminaire that keeps its battery, charger and test circuitry behind a cleanable room-side enclosure.
- Integrated Backup Battery
- Visible Charge Indicator
- Sealed Test Control
- Automatic Power-Failure Operation
مقدمة المنتج
The emergency light combines efficient LED optics with an internal or remote rechargeable battery and automatic transfer electronics. In normal operation the charger maintains the battery; when the monitored supply fails, the emergency driver powers the dedicated LED section. A small sealed indicator and test point remain visible from the room without adding an open switch aperture.
الخصائص الرئيسية
The charge-status indicator is sealed behind a clear window or membrane.
A recessed test button avoids a projecting dirt-catching control.
The battery compartment is separated from the room-facing optical chamber.
Wide-distribution optics spread useful egress light along the floor path.
مخاوف المنتج للعملاء
Emergency lighting must remain testable and visible while maintaining the smooth sealed surfaces expected inside a cleanroom.
An open test switch creates a recess that traps disinfectant.A sealed membrane or recessed protected button keeps the control wipeable.
Battery heat and service access disturb the lens cavity.A separate battery compartment isolates electrical maintenance from the optic.
A narrow beam leaves the floor route unevenly lit.Wide-distribution LED optics direct emergency output across the egress path.
Staff cannot tell whether the charger is active.A distinct low-intensity status indicator confirms normal charging condition.
تطبيقات نموذجية
Cleanroom escape routesAseptic room doorwaysControlled-area airlocksCritical utility passages
المعلمات الفنية
Typical configurable construction ranges for a cleanroom emergency LED light are listed below.
| المواد الأساسية | Powder-coated steel or polymer enclosure with LED optics, rechargeable battery, charger and transfer driver |
|---|---|
| سمك اللوحة | 70-150 mm enclosure depth |
| العرض الفعال | 180-450 mm exposed luminaire width |
| الحد الأقصى الطول | Up to 700 mm complete unit length |
| الصلب يواجه سمك | 0.8-1.2 mm formed steel housing when a metal enclosure is selected |
| الكثافة الأساسية | Approximately 1200-1450 kg/m³ for flame-retardant polymer housing components |
| الموصلية الحرارية | 0.20-0.35 W/(m·K) for the engineering-polymer enclosure |
| إنهاء السطح | Smooth white low-gloss exterior with clear status window and opal optical lens |
| نوع المشترك | Gasketed housing seam with sealed test membrane, retained optical cover and protected battery compartment |
| التخصيص | متوفر على أساس التطبيق المقصود وبيئة التشغيل. |
الخيارات المتاحة
Integral or remote battery packMaintained or non-maintained operationManual or self-test controlCeiling or wall mounting