Pencahayaan bilik bersih dan peralatan elektrik

Lampu kecemasan bilik bersih

A sealed emergency luminaire that keeps its battery, charger and test circuitry behind a cleanable room-side enclosure.
  • Integrated Backup Battery
  • Visible Charge Indicator
  • Sealed Test Control
  • Automatic Power-Failure Operation
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The emergency light combines efficient LED optics with an internal or remote rechargeable battery and automatic transfer electronics. In normal operation the charger maintains the battery; when the monitored supply fails, the emergency driver powers the dedicated LED section. A small sealed indicator and test point remain visible from the room without adding an open switch aperture.

Ciri-ciri Utama

A dedicated emergency driver transfers automatically when the normal lighting circuit is lost.

The charge-status indicator is sealed behind a clear window or membrane.

A recessed test button avoids a projecting dirt-catching control.

The battery compartment is separated from the room-facing optical chamber.

Wide-distribution optics spread useful egress light along the floor path.

Kebimbangan Produk Pelanggan

Emergency lighting must remain testable and visible while maintaining the smooth sealed surfaces expected inside a cleanroom.

An open test switch creates a recess that traps disinfectant.A sealed membrane or recessed protected button keeps the control wipeable.
Battery heat and service access disturb the lens cavity.A separate battery compartment isolates electrical maintenance from the optic.
A narrow beam leaves the floor route unevenly lit.Wide-distribution LED optics direct emergency output across the egress path.
Staff cannot tell whether the charger is active.A distinct low-intensity status indicator confirms normal charging condition.

Permohonan yang biasa

Cleanroom escape routesAseptic room doorwaysControlled-area airlocksCritical utility passages

Parameter teknikal

Typical configurable construction ranges for a cleanroom emergency LED light are listed below.

Bahan TerasPowder-coated steel or polymer enclosure with LED optics, rechargeable battery, charger and transfer driver
Ketebalan Panel70-150 mm enclosure depth
Lebar berkesan180-450 mm exposed luminaire width
Panjang maksimumUp to 700 mm complete unit length
Keluli Menghadapi Ketebalan0.8-1.2 mm formed steel housing when a metal enclosure is selected
Ketumpatan terasApproximately 1200-1450 kg/m³ for flame-retardant polymer housing components
Kekonduksian Terma0.20-0.35 W/(m·K) for the engineering-polymer enclosure
Kemasan permukaanSmooth white low-gloss exterior with clear status window and opal optical lens
Jenis BersatuGasketed housing seam with sealed test membrane, retained optical cover and protected battery compartment
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Integral or remote battery packMaintained or non-maintained operationManual or self-test controlCeiling or wall mounting

Planning a Cleanroom Emergency Light specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat