مقدمة المنتج
Cleanroom conduit encloses conductors inside stainless or coated metal tube and connects each section with compression or threaded fittings. Low-profile clips hold the route away from walls only where cleaning access is required, while sanitary escutcheons or bulkhead fittings close penetrations through cleanroom panels. Swept bends preserve cable pulling radius without open junctions.
الخصائص الرئيسية
Compression or threaded couplings maintain continuity through each straight joint.
Swept bends reduce pulling stress on control and power conductors.
Smooth support clips avoid deep saddles and exposed sharp threads.
Sealed bulkhead fittings close the wall around each conduit penetration.
مخاوف المنتج للعملاء
An exposed cable route must remain enclosed and continuous through bends, supports and panel penetrations, not only along the straight tube.
Loose cables sag and create irregular surfaces above equipment.Rigid conduit maintains a defined enclosed route.
Ordinary set-screw couplings leave open seams.Compression or threaded sealed fittings close the tube joint.
Tight elbows damage data cable during pulling.Large-radius swept bends preserve the conductor bend requirement.
A conduit hole bypasses the cleanroom wall seal.A gasketed bulkhead fitting clamps both sides of the panel penetration.
تطبيقات نموذجية
Exposed cleanroom power routesInstrument cable protectionEquipment service dropsWall and ceiling crossings
المعلمات الفنية
Typical configurable construction ranges for cleanroom electrical conduit are listed below.
| المواد الأساسية | SUS304/SUS316L or coated steel conduit with compression fittings, swept bends and sanitary bulkhead seals |
|---|---|
| سمك اللوحة | 1.0-2.0 mm conduit wall thickness |
| العرض الفعال | 16-63 mm nominal conduit diameter |
| الحد الأقصى الطول | Up to 6000 mm per straight tube section |
| الصلب يواجه سمك | 1.0-2.0 mm stainless or steel tube wall |
| الكثافة الأساسية | Approximately 7900-8000 kg/m³ for stainless conduit material |
| الموصلية الحرارية | 14-16 W/(m·K) for stainless tube |
| إنهاء السطح | Fine-brushed, electropolished or smooth white-coated exterior |
| نوع المشترك | Threaded or compression-sealed conduit couplings with gasketed panel bulkhead fittings |
| التخصيص | متوفر على أساس التطبيق المقصود وبيئة التشغيل. |
الخيارات المتاحة
Rigid stainless or coated steelFlexible liquid-tight equipment tailThreaded or compression fittingsWall, ceiling and floor bulkheads
Planning a Cleanroom Electrical Conduit specification?
أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

English
الألمانية
العربيةالحالي
الفرنسية
الإندونيسية
اليابانية
الكورية
اللغة الملاوية
البرتغالية
الروسية
الإسبانية
التايلاندية
اللغة التركية
اللغة الفيتنامية