غرفة نظيفة القناة الكهربائية

A smooth enclosed cable route using sealed tube, couplings and penetration fittings for exposed cleanroom electrical services.
  • Smooth Enclosed Cable Route
  • Sealed Compression Couplings
  • Hygienic Support Clips
  • Gasketed Wall Penetrations
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

Cleanroom conduit encloses conductors inside stainless or coated metal tube and connects each section with compression or threaded fittings. Low-profile clips hold the route away from walls only where cleaning access is required, while sanitary escutcheons or bulkhead fittings close penetrations through cleanroom panels. Swept bends preserve cable pulling radius without open junctions.

الخصائص الرئيسية

The closed tube protects cables and removes loose bundles from the cleaning surface.

Compression or threaded couplings maintain continuity through each straight joint.

Swept bends reduce pulling stress on control and power conductors.

Smooth support clips avoid deep saddles and exposed sharp threads.

Sealed bulkhead fittings close the wall around each conduit penetration.

مخاوف المنتج للعملاء

An exposed cable route must remain enclosed and continuous through bends, supports and panel penetrations, not only along the straight tube.

Loose cables sag and create irregular surfaces above equipment.Rigid conduit maintains a defined enclosed route.
Ordinary set-screw couplings leave open seams.Compression or threaded sealed fittings close the tube joint.
Tight elbows damage data cable during pulling.Large-radius swept bends preserve the conductor bend requirement.
A conduit hole bypasses the cleanroom wall seal.A gasketed bulkhead fitting clamps both sides of the panel penetration.

تطبيقات نموذجية

Exposed cleanroom power routesInstrument cable protectionEquipment service dropsWall and ceiling crossings

المعلمات الفنية

Typical configurable construction ranges for cleanroom electrical conduit are listed below.

المواد الأساسيةSUS304/SUS316L or coated steel conduit with compression fittings, swept bends and sanitary bulkhead seals
سمك اللوحة1.0-2.0 mm conduit wall thickness
العرض الفعال16-63 mm nominal conduit diameter
الحد الأقصى الطولUp to 6000 mm per straight tube section
الصلب يواجه سمك1.0-2.0 mm stainless or steel tube wall
الكثافة الأساسيةApproximately 7900-8000 kg/m³ for stainless conduit material
الموصلية الحرارية14-16 W/(m·K) for stainless tube
إنهاء السطحFine-brushed, electropolished or smooth white-coated exterior
نوع المشتركThreaded or compression-sealed conduit couplings with gasketed panel bulkhead fittings
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Rigid stainless or coated steelFlexible liquid-tight equipment tailThreaded or compression fittingsWall, ceiling and floor bulkheads