クリーンルーム機器と無菌施設の必需品のワンストップサプライヤー国際プロジェクト支援
Open mobile navigationClose mobile navigation
クリーンルーム照明 · 電気機器

クリーンルーム電気導管

A smooth enclosed cable route using sealed tube, couplings and penetration fittings for exposed cleanroom electrical services.
  • Smooth Enclosed Cable Route
  • Sealed Compression Couplings
  • Hygienic Support Clips
  • Gasketed Wall Penetrations
見積もりリクエスト 製品案内

商品紹介

Cleanroom conduit encloses conductors inside stainless or coated metal tube and connects each section with compression or threaded fittings. Low-profile clips hold the route away from walls only where cleaning access is required, while sanitary escutcheons or bulkhead fittings close penetrations through cleanroom panels. Swept bends preserve cable pulling radius without open junctions.

主要な特徴

The closed tube protects cables and removes loose bundles from the cleaning surface.

Compression or threaded couplings maintain continuity through each straight joint.

Swept bends reduce pulling stress on control and power conductors.

Smooth support clips avoid deep saddles and exposed sharp threads.

Sealed bulkhead fittings close the wall around each conduit penetration.

お客様の製品に関する懸念事項

An exposed cable route must remain enclosed and continuous through bends, supports and panel penetrations, not only along the straight tube.

Loose cables sag and create irregular surfaces above equipment.Rigid conduit maintains a defined enclosed route.
Ordinary set-screw couplings leave open seams.Compression or threaded sealed fittings close the tube joint.
Tight elbows damage data cable during pulling.Large-radius swept bends preserve the conductor bend requirement.
A conduit hole bypasses the cleanroom wall seal.A gasketed bulkhead fitting clamps both sides of the panel penetration.

典型的な用途

Exposed cleanroom power routesInstrument cable protectionEquipment service dropsWall and ceiling crossings

技術的なパラメータ

Typical configurable construction ranges for cleanroom electrical conduit are listed below.

コア材料SUS304/SUS316L or coated steel conduit with compression fittings, swept bends and sanitary bulkhead seals
パネルの厚さ1.0-2.0 mm conduit wall thickness
有効幅16-63 mm nominal conduit diameter
最大長さUp to 6000 mm per straight tube section
鋼鉄の厚さを直面する1.0-2.0 mm stainless or steel tube wall
コア密度Approximately 7900-8000 kg/m³ for stainless conduit material
熱伝導率14-16 W/(m·K) for stainless tube
表面仕上げFine-brushed, electropolished or smooth white-coated exterior
ジョイントタイプThreaded or compression-sealed conduit couplings with gasketed panel bulkhead fittings
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

Rigid stainless or coated steelFlexible liquid-tight equipment tailThreaded or compression fittingsWall, ceiling and floor bulkheads

Planning a Cleanroom Electrical Conduit specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する
メール送信 WhatsApp WeChat

ホーム

製品

ニュース

会社概要

お問い合わせ